Preliminary evaluation of dual imaging plate intraoral radiography

Abstract: Purpose: This study evaluated the contrast-to-noise ratio (CNR), spatial resolution, and subjective quality of dual imaging plates (DIP) intraoral radiography. Methods:The DIP and conventional single IP (CSIP) methods both used YCR DT-1 imaging plates (Yoshida Co.). The DIP, comprising a front IP (FIP) and back IP (BIP), was constructed. DIP images were synthesized from the FIP and BIP images. An aluminum step phantom was used to measure the CNR. A line pair gauge was used to measure the spatial imaging resolu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…Watanabe et al [12] reported that the contrast-to-noise ratio increased and the noise decreased in DIP images in which FIP and BIP were synthesized in intraoral radiography. Another problem with IP is that scratches and dust cause artifacts.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Watanabe et al [12] reported that the contrast-to-noise ratio increased and the noise decreased in DIP images in which FIP and BIP were synthesized in intraoral radiography. Another problem with IP is that scratches and dust cause artifacts.…”
Section: Discussionmentioning
confidence: 99%
“…Six sets of DIPs (12 IPs; Digora Optime Imaging Plate size 2, PaloDEx Group Oy, Tuusula, Finland) were used in the study. Following the method of Watanabe et al [12], the thin iron plate of the FIP was first peeled off. The FIP and BIP were stacked and placed in a plastic bag (disposable cover for the Digora Optime imaging plate, size 2, Tanaka-ya Co., Tokyo, Japan).…”
Section: Dip Preparationmentioning
confidence: 99%
See 2 more Smart Citations
“…In research (Watanabe et al, 2022) using a CR and PSP system in the form of a Dual Imaging Plate (DIP) and Conventional Single Imaging Plate (CSIP) with samples using a Porcine Mandible Embedded in Acrylic Resin phantom, aiming to evaluate the CNR, spatial resolution and subject quality of the DIP. The results are that the CNR value on DIP is higher when compared to the CNR value on FIP, the decrease in spatial resolution is limited on DIP, and the subjective image quality on DIP is higher than on FIP.…”
Section: Digital Image Data Analysis Of Intraoral Dental Radiographymentioning
confidence: 99%