2019
DOI: 10.1002/nsg.12076
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary assessment on the application of biochar and spectral‐induced polarization for wastewater treatment

Abstract: In this work, we explore the use of biochar as a remediation agent, and the sensitivity of the spectral‐induced polarization method as a remediation monitoring aid. Biochar amended columns were fully saturated with industrial wastewater (olive oil mill waste) with very high concentration of phenols (∼2485 mg/L) and other substances. The biochar‐amended columns achieved very high removal rates of phenols compared to the control (sand only). Geophysical monitoring over the duration of the experiment (10 days) sh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 66 publications
(95 reference statements)
0
8
0
Order By: Relevance
“…A preliminary geophysical investigation was done by Siddiq et al [3] in order to correlate SIP parameters (real and imaginary conductivity) to the interactions (and therefore removal) of As(V) with biochar. Recent published work can provide detailed discussion on SIP and the used experimental set-up [3,51]. In brief, three laboratory columns of 240 mm length and 38 mm diameter, were prepared in accordance with previous work [51].…”
Section: Sip Monitoringmentioning
confidence: 99%
See 3 more Smart Citations
“…A preliminary geophysical investigation was done by Siddiq et al [3] in order to correlate SIP parameters (real and imaginary conductivity) to the interactions (and therefore removal) of As(V) with biochar. Recent published work can provide detailed discussion on SIP and the used experimental set-up [3,51]. In brief, three laboratory columns of 240 mm length and 38 mm diameter, were prepared in accordance with previous work [51].…”
Section: Sip Monitoringmentioning
confidence: 99%
“…Recent published work can provide detailed discussion on SIP and the used experimental set-up [3,51]. In brief, three laboratory columns of 240 mm length and 38 mm diameter, were prepared in accordance with previous work [51]. One column was filled with sand and served as a control, while the other two were filled with BC-500 adjusted sand at 5% and 10% by weight, respectively.…”
Section: Sip Monitoringmentioning
confidence: 99%
See 2 more Smart Citations
“…The key to the effectiveness of the adsorption method in treating uranium-containing wastewater lies in the selection of the adsorbent material [22][23][24].…”
Section: Introductionmentioning
confidence: 99%