2022
DOI: 10.1016/j.jbc.2022.101814
|View full text |Cite
|
Sign up to set email alerts
|

Prefusion spike protein conformational changes are slower in SARS-CoV-2 than in SARS-CoV-1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
23
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(27 citation statements)
references
References 91 publications
3
23
0
Order By: Relevance
“…139, 140 Another insightful atomistic simulation study of the kinetics of conformational changes in the SARS-CoV-2 and CoV-1 S proteins showed that a salt bridge R319-D745 between the RBD of the active up protomer and the S2 region in the CoV-2 S protein contributes to the relative stability of the active spike state and the differential dynamic behavior between SARS CoV-2 and SARS CoV-1 spike trimers. 141…”
Section: Resultsmentioning
confidence: 99%
“…139, 140 Another insightful atomistic simulation study of the kinetics of conformational changes in the SARS-CoV-2 and CoV-1 S proteins showed that a salt bridge R319-D745 between the RBD of the active up protomer and the S2 region in the CoV-2 S protein contributes to the relative stability of the active spike state and the differential dynamic behavior between SARS CoV-2 and SARS CoV-1 spike trimers. 141…”
Section: Resultsmentioning
confidence: 99%
“…The combination of equilibrium and non-equilibrium MD simulations has proven effective for investigating biological challenges. 12,5664 In this work, the YidC independent insertion mechanism was studied using non-equilibrium targeted MD (TMD) as implemented within the colvars module of NAMD. 65 TMD simulation was performed on the final conformation of the pose 1 system obtained from the 550 ns equilibrium trajectory in order to transfer the Pf3 peptide to the periplasmic side of the membrane, as seen in pose 2.…”
Section: Methodsmentioning
confidence: 99%
“…In the NPT ensemble at 310 K, 1 µ s of equilibrium MD simulations were performed under periodic boundary conditions for each system. In the simulations, a Langevin integrator with a damping coefficient of γ =0.5 ps − 1 and 1 atm pressure was maintained using the Nose-Hoover Langevin piston method 56,57 18,5867 .…”
Section: Methodsmentioning
confidence: 99%
“…The preliminary simulations were run on TACC Stampede supercomputer. Subsequently, the production run for each model was increased to 400 ns with a timestep of 2.5 fs on Anton2 58 . Every 240 picoseconds, conformations were gathered on Anton2.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation