4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003.
DOI: 10.1109/demped.2003.1234600
|View full text |Cite
|
Sign up to set email alerts
|

Predictive diagnostics for the main field winding and rotating rectifier assembly in the brushless synchronous generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
11
0

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…The proposed approach eliminates the brushes and/or rotating rectifier diodes that are often used in the wound-field synchronous generator [5]. Although both the proposed approach and the induction machine-based approach can be implemented using an inverter as the reactive power source, the proposed approach also has potential efficiency advantages due to elimination of rotor I 2 R conduction losses.…”
Section: Introductionmentioning
confidence: 97%
“…The proposed approach eliminates the brushes and/or rotating rectifier diodes that are often used in the wound-field synchronous generator [5]. Although both the proposed approach and the induction machine-based approach can be implemented using an inverter as the reactive power source, the proposed approach also has potential efficiency advantages due to elimination of rotor I 2 R conduction losses.…”
Section: Introductionmentioning
confidence: 97%
“…They are capable of generating AC power at specified frequency, also called as synchronous generator and these machines are the largest energy converters in the world. Based on the excitation system, they can be grouped into brushed and brushless alternators [2]. The brushed alternator, also called as rotating armature type are used only in alternators of low power rating and generally is not used to supply electric power in large quantities.…”
Section: Introductionmentioning
confidence: 99%
“…The main proposed indicators have dealt on ratio monitoring of the fundamental component regarding the dc level [1], as well as on the amplitude oversight of the component related to twice rated frequency [3]. In [4], others authors have suggested to measure the brushless transfer characteristic, given by the ratio of the generator"s output voltage and the exciter field current. On the other hand, many diagnosis techniques based on machine"s models [5], [6], [7], [8] and control algorithms [9], [10] have been suggested.…”
Section: Introductionmentioning
confidence: 99%