1989
DOI: 10.1016/0045-6535(89)90196-3
|View full text |Cite
|
Sign up to set email alerts
|

Prediction of vapor pressures, boiling points and enthalpies of fusion for twenty-nine halogenated dibenzo-p-dioxins and fifty-five dibenzofurans by a vapor pressure correlation method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

16
82
7

Year Published

1993
1993
2014
2014

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 123 publications
(106 citation statements)
references
References 8 publications
16
82
7
Order By: Relevance
“…Results from both sampling sites show that atmospheric PCDD/Fs tended to be distributed between the gaseous and particulate phases based on molecular weight; the higher chlorinated congener occupied a higher particulate fraction. Moreover, PCDD homologues tended to be more associated with particles than the equivalent PCDFs, probably due to the slightly lower vapour pressures of PCDDs (Rordorf, 1989). The above findings are comparable with those reported earlier (Lohmann et al, 1998;Chao et al, 2004;Wu et al, 2009;Xu et al, 2009;Lin et al, 2010a).…”
Section: Gas-particle Partitioning Of Pcdd/fssupporting
confidence: 82%
“…Results from both sampling sites show that atmospheric PCDD/Fs tended to be distributed between the gaseous and particulate phases based on molecular weight; the higher chlorinated congener occupied a higher particulate fraction. Moreover, PCDD homologues tended to be more associated with particles than the equivalent PCDFs, probably due to the slightly lower vapour pressures of PCDDs (Rordorf, 1989). The above findings are comparable with those reported earlier (Lohmann et al, 1998;Chao et al, 2004;Wu et al, 2009;Xu et al, 2009;Lin et al, 2010a).…”
Section: Gas-particle Partitioning Of Pcdd/fssupporting
confidence: 82%
“…According to the results of contribution fraction of particle phase, the PCDD/F and PCB congeners with higher chlorine numbers occupied a higher particle fraction. Compare the particulate fraction of PCDDs and PCDFs, PCDD homologues is apt to attaching to particles than the equivalent PCDFs, which might owing to the vapor pressure of PCDFs are slightly less than PCDDs (Rordorf, 1989). Comparable results can also be found in previous studies (Lohmann and Jones, 1998;Chao et al, 2004;Lin et al, 2010a).…”
Section: Gas-particle Partitioningsupporting
confidence: 76%
“…It was found that the measured and simulated particulate fractions of PCDD/Fs increased as the number of chlorinated substitutes increased; the higher chlorinated congeners (particularly HCDD/F and OCDD/F) were predominant in the particle phase (Tables 4 and 5). The total PCDD was found predominantly associated with particles at all sites of both measured and simulated results, probably due to lower vapor pressures for the PCDDs (Rordorf, 1989). Additionally, the total PCDD/Fs bound to particles increased slightly with decreasing temperature, the highest level was observed in fall (average of 60.2-72.5%), while the lowest one in spring for all sites (average of 42.8-58.6%).…”
Section: Gas-particle Partitioning Of Pcdd/fs and Pcbsmentioning
confidence: 76%