1998
DOI: 10.1016/s0017-9310(98)00067-2
|View full text |Cite
|
Sign up to set email alerts
|

Prediction of thermal contact resistance between polished surfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
28
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 94 publications
(30 citation statements)
references
References 5 publications
2
28
0
Order By: Relevance
“…Using a 10 µm hemisphere for the model particle, the contact conductance is estimated at 46 kWm −2 K −1 . This value initially seems high in comparison to metal-metal contacts which have a conductance on the order of a few kWm −2 K −1 [9], however the contact conductance of graphene and highly ordered graphite can easily be tens of MWm −2 K −1 [10]. The loose bonding of the graphite with the surface of the optic and the agglomerated nature of the graphite flakes may explain the lower value calculated.…”
Section: Discussionmentioning
confidence: 78%
“…Using a 10 µm hemisphere for the model particle, the contact conductance is estimated at 46 kWm −2 K −1 . This value initially seems high in comparison to metal-metal contacts which have a conductance on the order of a few kWm −2 K −1 [9], however the contact conductance of graphene and highly ordered graphite can easily be tens of MWm −2 K −1 [10]. The loose bonding of the graphite with the surface of the optic and the agglomerated nature of the graphite flakes may explain the lower value calculated.…”
Section: Discussionmentioning
confidence: 78%
“…A typical thermal solution for a microelectronic system utilizes a thermal interface material (TIM) [1][2][3][4][5][6] between the die and the heat spreader, and between the heat spreader and the heat sink. The TIM is used to reduce the contact resistance arising from the incomplete contact between two solid surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Numerical results show that the long wavelength cut-off has an important effect on the contact conductance, whereas the sampling interval and the fractal dimension are less important. [25] In this study guarded hot plate method for thermal conductivity measurements was choosen to determine temperature drops across interfaces. It was shown that a general theory can be modified to give a good estimation of the thermal resistance with a variety of interface materials.…”
Section: M Yovanovich (2005)mentioning