Prediction of the dynamic contact resistance of circuit breaker based on the kernel partial least squares

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 22 publications
(24 reference statements)
0
9
0
Order By: Relevance
“…The implementation of this technique and its repeatability have been recently focused in many efforts. Reference [38]- [42] indicated that the measured resistance in this test is dependent on the injected DC current and opening velocity. The resistance decreases with an increase in the injectedcurrent and decrease of the velocity.…”
Section: Dynamic Resistance Measurementmentioning
confidence: 93%
See 2 more Smart Citations
“…The implementation of this technique and its repeatability have been recently focused in many efforts. Reference [38]- [42] indicated that the measured resistance in this test is dependent on the injected DC current and opening velocity. The resistance decreases with an increase in the injectedcurrent and decrease of the velocity.…”
Section: Dynamic Resistance Measurementmentioning
confidence: 93%
“…DRM could provide valuable evidence on the condition of the main and arc contacts. However, the main weak point of this approach is infeasibility in real-time assessment [42] [55]- [57]. Consequently, an online condition assessment method will be required to evaluate the status of the contacts encapsulated in an insulation medium.…”
Section: F Future Viable Visionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Perform DRM tests at low contact speed. The lower the contact speed, the more repeatable the dynamic contact resistance curves are [5,6,9,13]. When the DC injected current (I d ) is 100 A, the contact speed should be 0.002-0.2 m/s, which is lower than the rated speed of the tested circuit breaker [5,9]; when I d is up to 1300 A, the influence of the contact speed on DRM test results can be ignored [6].…”
Section: Introductionmentioning
confidence: 99%
“…In other words, this method does not take the friction heat in DRM tests into consideration. Liu et al [13] measured the effective contact area of the contact finger by the laser scanning microscope, and it found that the current rise made the effective contact area bigger and led to the decrease of the resistance. However, it did not explain how the current rise made the effective contact area bigger, and it did not put forward a determination method for the amplitude of I d .…”
Section: Introductionmentioning
confidence: 99%