“…This behaviour is in good agreement with the curve obtained by Brooks et al 8 , although in the present case their assumption that the -6-NLR-TP-2002-226 source length is much smaller than the distance to the array is not satisfied (both are 0.6 m). The ACF is also similar to the calibration function found by Ostertag et al 10 for similar conditions. The shape of the curve can be qualitatively understood from the fact that the scan levels for a group of incoherent sources are equal to the sum of the scan levels from the individual sources.…”
Section: Numerical Resultssupporting
confidence: 88%
“…It was found that both peak and integrated response levels varied significantly as a function of phase and coherence level between the two sources. Ostertag et al 10 investigated trailing-edge noise from a flat plate and determined both theoretically and experimentally an array transfer function relating the levels in the acoustic source plots to absolute sound levels in the farfield. Good agreement between the measured and predicted array calibration function was found.…”
“…This behaviour is in good agreement with the curve obtained by Brooks et al 8 , although in the present case their assumption that the -6-NLR-TP-2002-226 source length is much smaller than the distance to the array is not satisfied (both are 0.6 m). The ACF is also similar to the calibration function found by Ostertag et al 10 for similar conditions. The shape of the curve can be qualitatively understood from the fact that the scan levels for a group of incoherent sources are equal to the sum of the scan levels from the individual sources.…”
Section: Numerical Resultssupporting
confidence: 88%
“…It was found that both peak and integrated response levels varied significantly as a function of phase and coherence level between the two sources. Ostertag et al 10 investigated trailing-edge noise from a flat plate and determined both theoretically and experimentally an array transfer function relating the levels in the acoustic source plots to absolute sound levels in the farfield. Good agreement between the measured and predicted array calibration function was found.…”
“…Agreement was obtained with the formulation given in equation (1). In addition, measurements of the trailing-edge scattering noise have been made by Brooks and Hodgson [5] and more recently by Ostertag et al [15], con"rming the result given in equation (1). 4.…”
“…al. [8] in 2000, of Hu [9] in 2005 and of Takaishi [10] 2007. In these works, the numerical method is not thoroughly described and a standard BEM (not accelerated) is used.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.