Predicting 3D body shape and body composition from conventional 2D photography

Abstract: Purpose Total and regional body composition are important indicators of health and mortality risk, but their measurement is usually restricted to controlled environments in clinical settings with expensive and specialized equipment. A method that approaches the accuracy of the current gold standard method, dual‐energy x‐ray absorptiometry (DXA), while only requiring input from widely available consumer grade equipment, would enable the measurement of these important biometrics in the wild, enabling data collec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 27 publications
(34 citation statements)
references
References 20 publications
(43 reference statements)
0
34
0
Order By: Relevance
“…High (+3 SD) and low (−3 SD) states of each PC were generated by varying each PC separately with all others held as equal to zero. These PC weight vectors were inverted back to Cartesian space and added to the sex‐specific mean body shape for visualization (26).…”
Section: Methodsmentioning
confidence: 99%
“…High (+3 SD) and low (−3 SD) states of each PC were generated by varying each PC separately with all others held as equal to zero. These PC weight vectors were inverted back to Cartesian space and added to the sex‐specific mean body shape for visualization (26).…”
Section: Methodsmentioning
confidence: 99%
“…Although the authors properly acknowledged that the small sample size limited the strength of their study, they suggested that re-evaluation of DXA body composition calibration standard is required to optimize the accuracy of the method. Consistently, the recent studies performed with a Hologic device reported that the NHANES BCA calibration option was disabled for scan analysis (36)(37)(38)(39). Although further studies are required to establish whether the NHANES BCA calibration option should always be disabled or must be used in the selected subgroups of patients (e.g., obese patients), it is recommended that a serial evaluation of the same patient to assess the body composition changes is performed with the same software configuration (that should be specified in the report).…”
Section: Calibration Issuesmentioning
confidence: 60%
“…Prior seminal studies have suggested that estimation of fat distribution using various proxies for medical imaging may be feasible, but have several limitations. [19][20][21][22][23][24][25][26][27][28] First, most studies in this area have focused on predicting overall fat and fat-free mass rather than specific fat depots, which is likely to be significantly more diffcult. [19][20][21][22][23]28 Second, no prior study has aimed to predict ratios between fat depots, which are poorly captured by BMI and waist circumference and hence may add the most clinical value.…”
Section: Introductionmentioning
confidence: 99%
“…[19][20][21][22][23][24][25][26][27][28] First, most studies in this area have focused on predicting overall fat and fat-free mass rather than specific fat depots, which is likely to be significantly more diffcult. [19][20][21][22][23]28 Second, no prior study has aimed to predict ratios between fat depots, which are poorly captured by BMI and waist circumference and hence may add the most clinical value. [24][25][26][27] Third, prior studies in this area have been limited by sample sizes of up to several hundred healthy participants, limiting the ability to perform robust cross-validation.…”
Section: Introductionmentioning
confidence: 99%