1999
DOI: 10.1039/a809854i
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration of ultratrace rare earth elements in seawater with 8-hydroxyquinoline immobilized polyacrylonitrile hollow fiber membrane for determination by inductively coupled plasma mass spectrometry

Abstract: 8-Hydroxyquinoline immobilized on polyacrylonitrile hollow fiber membrane was synthesized and used for the preconcentration of rare earth elements (REEs) and the separation of the matrix in seawater prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS). Both the capacity and chemical stability of the modified polyacrylonitrile hollow fiber membrane have been evaluated. The optimum experimental conditions, such as pH, sample flow rate, volume of eluents, were investigated. The co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
44
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 92 publications
(45 citation statements)
references
References 24 publications
0
44
1
Order By: Relevance
“…115 In was added as an internal standard to monitor matrix effects and signal drifting. General instrumental operating conditions and sample digestion methods have been described previously (Wen et al, 1999). The analyses were carried out in triplicate.…”
Section: Determination Of Reesmentioning
confidence: 99%
“…115 In was added as an internal standard to monitor matrix effects and signal drifting. General instrumental operating conditions and sample digestion methods have been described previously (Wen et al, 1999). The analyses were carried out in triplicate.…”
Section: Determination Of Reesmentioning
confidence: 99%
“…In another supporting electrolyte the concentrations of La, Ce, Pr and Nd were defined as 10.55, 26.98, 2.29 and 8.12 lg/mL, respectively. A portion of 0.500 g of soil samples were equilibrated with 20 mL of 0.01 mol/L of organic acid-0.01 mol/L of Ca(NO 3 ) 2 solutions containing REEs at the above mentioned concentration levels under the conditions of continuous shaking for 24 h. Then, the samples were centrifuged at 6000 for 0.5 h, the pH values of equilibration solutions were determined again, and the concentrations of REEs in the equilibration solutions remained were determined as well by using inductively coupled plasma mass spectrometry (ICP-MS) (Wen et al, 1999).…”
Section: Effect Of Organic Ligands and Equilibrium Solution Ph On Adsmentioning
confidence: 99%
“…Indium was added as an internal standard to monitor matrix effects and signal drift. The details were reported previously by Wen et al (1999).…”
Section: Determination Of Reesmentioning
confidence: 99%
“…21 Much research work has been done to find the most efficient way to immobilize 8-hydroxyquinoline on a number of different substrates through chemical modifications or physical adsorption procedures for the preconcentration of trace elements. [22][23][24][25] Trace element determination methods have also involved the precomplexation of analytes with a solution of the ligand, and then concentration on different adsorbents. 26,27 Among these supports, silica gel is the most often used material.…”
Section: Introductionmentioning
confidence: 99%