2007
DOI: 10.1002/cjoc.200790343
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration and Determination of Chromium Species Using Octadecyl Silica Membrane Disks and Flame Atomic Absorption Spectrometry

Abstract: A novel and selective method for the fast determination of trace amounts of chromium species in water samples has been developed. The procedure is based on the selective formation of chromium diethyldithiocarbamate complexes at different pH in the presence of Mn(II) as an enhancement agent of chromium signals followed by elution with organic eluents and determination by atomic flame absorption spectrometry. The maximum capacity of the employed disks was found to be (396±3) µg and (376±2) µg for Cr(III) and Cr(… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 35 publications
0
17
0
Order By: Relevance
“…The method developed was simple, reliable, and precise for determining Hg(II) in water. Also, the proposed method was free of interference compared to conventional procedures to determine Hg(II) (Choi and Choi, 2003;Moghimi, 2006;Tuzen et al, 2009a). The method can be successfully applied to the separation and determination of Hg(II) in binary mixtures.…”
Section: Discussionmentioning
confidence: 92%
See 4 more Smart Citations
“…The method developed was simple, reliable, and precise for determining Hg(II) in water. Also, the proposed method was free of interference compared to conventional procedures to determine Hg(II) (Choi and Choi, 2003;Moghimi, 2006;Tuzen et al, 2009a). The method can be successfully applied to the separation and determination of Hg(II) in binary mixtures.…”
Section: Discussionmentioning
confidence: 92%
“…Ultra pure organic solvents were obtained from Merck Chemical Company, Darmstat, Germany, and high Purity deionized water was used throughout the experiments and 3-chloro propyl trimethoxysilane was received from Aldrich Chemical, USA. Organic solvents were dried according to conventional methods (Moghimi et al, 2006). For all solutions double distilled water was used and the buffer solutions were prepared from 1.0 M sodium acetate to which different volumes of 1.0 M HCl; HNO3 were mixed.…”
Section: Reagents and Materialsmentioning
confidence: 99%
See 3 more Smart Citations