2012
DOI: 10.1039/c2an16053f
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration and detection of chlorinated organic compounds and benzene

Abstract: Remote and automated detection of organic compounds in subsurface aquifers is crucial to superfund monitoring and environmental remediation. Current monitoring techniques use expensive laboratory instruments and trained personnel. The use of a filled tubular preconcentrator combined with a chemicapacitive detector array presents an attractive option for the unattended monitoring of these compounds. Five preconcentrator materials were exposed to common target compounds of subsurface remediation projects (1,1,2-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(21 citation statements)
references
References 15 publications
(10 reference statements)
0
21
0
Order By: Relevance
“…In a related application, PIM-1 has been used as a preconcentrator medium for adsorbing organics from air which can then be desorbed by heating into a conventional sensor [139,140]. For this application, the thermal stability of PIMs is of importance.…”
Section: Sensorsmentioning
confidence: 99%
“…In a related application, PIM-1 has been used as a preconcentrator medium for adsorbing organics from air which can then be desorbed by heating into a conventional sensor [139,140]. For this application, the thermal stability of PIMs is of importance.…”
Section: Sensorsmentioning
confidence: 99%
“…The stainless steel tube was inserted into a ceramic outer tube, soldered to threaded brass ends, and then filled with absorbent media. 20 The difference between this preconcentrator and our previous device was the replacement of the press-fit connections with threaded tube-end fittings for gas-tight connections. The preconcentrator is resistively heated by applying a controlled voltage between the brass electrodes for short durations.…”
Section: Methodsmentioning
confidence: 99%
“…The polymer-filled microcapacitors, or chemicapacitors, were fabricated by Seacoast Science, and their structure has been extensively reported on. 20,23,26,27 The chemicapacitor array chips used in the VIM were 2 × 5 mm and contained 10 capacitors, 8 of which were filled with polymer and measured. † Each chemicapacitor was filled with a different polymer.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations