2020
DOI: 10.1097/j.jcrs.0000000000000318
|View full text |Cite
|
Sign up to set email alerts
|

Precision pulse capsulotomy: performance metrics and utility in routine and complex cases

Abstract: Purpose: To evaluate precision pulse capsulotomy (PPC) performance. Setting: University and private practice in the United States and South Korea. Design: Multicenter retrospective analysis. Methods: The surgical videos of 337 cataract surgeries with PPC capsulotomy performed by 4 surgeons at 4 centers were used to assess capsulotomy outcomes including completion… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…Prior experience reported in the literature suggests that complications in early cases are primarily related to not ensuring complete capsule contact or a failure to fully retract the push rod used to insert the device, which can interfere with suction. 15 There are limitations to the current study. While numbers were relatively high, the retrospective nature of the data collected reduced the level of detail that could be extracted from the clinical records.…”
Section: Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…Prior experience reported in the literature suggests that complications in early cases are primarily related to not ensuring complete capsule contact or a failure to fully retract the push rod used to insert the device, which can interfere with suction. 15 There are limitations to the current study. While numbers were relatively high, the retrospective nature of the data collected reduced the level of detail that could be extracted from the clinical records.…”
Section: Discussionmentioning
confidence: 88%
“…13 Previous clinical results have demonstrated the efficacy of the device. [14][15][16] As with the femtosecond laser systems, there is some evidence that an automated capsulotomy that does not induce zonular stress may be helpful in complicated cases. 15 The purpose of the current study was to retrospectively review refractive outcomes and complications in a high number of cases completed using the PPC device, comparing them to a similar set of cases completed using a manual CCC technique.…”
Section: Introductionmentioning
confidence: 99%
“…[11][12][13][14][15] The learning curve has been reported to be favorable, and the experience of 4 surgeons has been described. 11 Several device operating principles underlying PPC creation suggest that this technology may also be useful in cases of white cataract. This includes the technology's ability to function in the presence of poor capsular visibility, the near-instantaneous (4 milliseconds) creation of the whole capsulotomy to rapidly release intralenticular pressure, and the demonstrated added capsular edge strength resulting from PPC's unique cutting effect.…”
mentioning
confidence: 99%
“…11–15 The learning curve has been reported to be favorable, and the experience of 4 surgeons has been described. 11…”
mentioning
confidence: 99%
See 1 more Smart Citation