1993
DOI: 10.1111/j.1399-6576.1993.tb03777.x
|View full text |Cite
|
Sign up to set email alerts
|

Precision of a new bedside method for estimation of the circulating blood volume

Abstract: The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and after ventilation with a gas mixture containing 20-50 ml of CO for a period of 10-15 min. A special Water's to and fro system was designed in order to avoid any leakage when measuring during intermittent positive pressu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
13
0

Year Published

1994
1994
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 11 publications
4
13
0
Order By: Relevance
“…Although CAP systematically overestimated Hb mass by 1.7% compared with VEN, the technical error of measurement (2.7%) compares favourably with previous reports for the venepuncture technique: 0.8% (Burge and Skinner 1995), 1.9% (Gore et al 1997), 2.5% (Fogh-Andersen et al 1990) and 5.1% (Christensen et al 1993). This level of reproducibility is quite acceptable for the majority of experimental circumstances and would for example be suited to longitudinal studies involving exposure to environmental stimuli that may alter Hb mass.…”
Section: Discussionsupporting
confidence: 79%
“…Although CAP systematically overestimated Hb mass by 1.7% compared with VEN, the technical error of measurement (2.7%) compares favourably with previous reports for the venepuncture technique: 0.8% (Burge and Skinner 1995), 1.9% (Gore et al 1997), 2.5% (Fogh-Andersen et al 1990) and 5.1% (Christensen et al 1993). This level of reproducibility is quite acceptable for the majority of experimental circumstances and would for example be suited to longitudinal studies involving exposure to environmental stimuli that may alter Hb mass.…”
Section: Discussionsupporting
confidence: 79%
“…The volume of CO administered was 50 ml at sea level and 60 ml at high altitude. Rebreathing time was 10 min to ensure that maximal COHb% had been reached (Fogh-Andersen et al 1990; Thomsen et al 1991;Christensen et al 1993;Burge and Skinner 1995).…”
Section: Co Rebreathing Methodsmentioning
confidence: 99%
“…Used in connection with the new generation of multiwave length spectrophotometers the carbon monoxide (CO) rebreathing method has been found to facilitate very accurate and precise measurements of blood and plasma volumes (Fogh-Andersen et al 1990;Thomsen et al 1991;Christensen et al 1993;Burge and Skinner 1995). The purpose of this study was to compare the volume of distribution of albumin (Evans' blue method, PV Evans' ) with measurements of plasma volume obtained by the CO rebreathing method (PV CO ) in normal subjects at sea level and again 24 h after a rapid, passive ascent to 4,350 m. Furthermore, the eect of acute hypoxaemia on TER Alb was measured.…”
Section: Introductionmentioning
confidence: 99%
“…Red blood cell volume, blood volume and plasma volume were determined by a carbon monoxide rebreathing method (Circulating Blood Volume System, CBVMedical, Denmark) (Christensen et al 1993;Poulsen et al 1998). Briefly, after a 20-min resting period in a sitting position, the subjects breathed into a closed circuit, including a 2-l rebreathing bag, and a carbon dioxide absorber.…”
Section: Intra-vascular Compartmentsmentioning
confidence: 99%
“…Hematocrit (Hct) was measured in triplicate by a microcentrifuge. Total hemoglobin mass (nHb), red blood cell volume (V RBC ), plasma volume (PV) and blood volume (BV) were then obtained by calculation (Christensen et al 1993).…”
Section: Intra-vascular Compartmentsmentioning
confidence: 99%