1986
DOI: 10.1103/physreva.33.774
|View full text |Cite
|
Sign up to set email alerts
|

Precision measurement of the 1sLamb shift in hydrogenlike argon

Abstract: Precision measurements of the absolute wavelengths of the Lyman a doublet (2p'py _ is 2S) in hydrogen-like argon (Ar 1 7 +), as well as those of some strong dielectronic satellites, are reported. The Alcator C tokamak plasma was seeded with trace amounts of argon and the emission spectra were taken with a high resolution, crystal X-ray spectrometer. In situ wavelength calibration was achieved by utilizing the potassium Ka lines from a KCl fluorescence source. For the Lya 2 line, a precision of 11 ppm was achie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
38
0

Year Published

1987
1987
2015
2015

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(38 citation statements)
references
References 7 publications
0
38
0
Order By: Relevance
“…Absolute wavelength calibration for the tangentially viewing spectrometer was obtained from the potassium Ka lines generated from a KCl fluorescence x-ray source [40]. There was no wavelength calibration for the spectrometer array viewing at +60, so for those measurements all velocities are relative to the pre-RF conditions.…”
Section: Experiments Descriptionmentioning
confidence: 99%
“…Absolute wavelength calibration for the tangentially viewing spectrometer was obtained from the potassium Ka lines generated from a KCl fluorescence x-ray source [40]. There was no wavelength calibration for the spectrometer array viewing at +60, so for those measurements all velocities are relative to the pre-RF conditions.…”
Section: Experiments Descriptionmentioning
confidence: 99%
“…Si and Al were also injected into Alcator C plasmas with a laser blow-off system. Lines from hydrogen- [33,34] and helium-like [35][36][37] charge states are taken to have well known wavelengths, either measured or calculated. Experimental wavelengths were determined by performing a least squares fit to observed spectra using gaussian line shapes; measured line widths are dominated by Doppler broadening.…”
Section: Experiments Descriptionmentioning
confidence: 99%
“…X-ray spectra were recorded with a von Hamos type x-ray spectrometer [19], whose line of sight is tangent to the plasma major radius, pointing in the counter clockwise direction, as seen from above. Rotation velocities have been determined from the Doppler shifts of the argon Lyman a doublet [20] (1s 'Si. -2p 2 Pa at 3731.1 mA, and is 22 iSi -2p 2 P, at 3736.5 mA) and the 2p' -(2p-)a4dA transition [21] in Mo 3 2+ at 3739.8 mA.…”
Section: Experiments Descriptionmentioning
confidence: 99%
“…Molybdenum is an intrinsic impurity, usually present in all Alcator C-Mod discharges.. Absolute wavelength calibration was obtained from the potassium K, lines generated from a KC1 fluorescence x-ray source [20].…”
Section: Experiments Descriptionmentioning
confidence: 99%