1972
DOI: 10.1016/0022-1902(72)80311-7
|View full text |Cite
|
Sign up to set email alerts
|

Precision measurement of half-life and specific activity of 236U

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1973
1973
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…Alpha-particle counting at a defined low solid angle is amongst the most accurate primary standardization methods for alpha-emitting radionuclides, with attainable accuracies around 0.1% [88][89][90][91]. It has been applied in various standardization exercises [17,92,93], but also in the frame of half-life determinations of long-lived radionuclides [94][95][96][97][98][99][100]. A special application is the standardization of radon gas that is condensed on a cold circular disc [56,101,102].…”
Section: Counting At a Defined Solid Angle (Dsa)mentioning
confidence: 99%
“…Alpha-particle counting at a defined low solid angle is amongst the most accurate primary standardization methods for alpha-emitting radionuclides, with attainable accuracies around 0.1% [88][89][90][91]. It has been applied in various standardization exercises [17,92,93], but also in the frame of half-life determinations of long-lived radionuclides [94][95][96][97][98][99][100]. A special application is the standardization of radon gas that is condensed on a cold circular disc [56,101,102].…”
Section: Counting At a Defined Solid Angle (Dsa)mentioning
confidence: 99%
“…The uncertainty of counting at a defined solid angle by several institutes, including IRMM (formerly CBNM) [8,9], LRL [10], NIST [11], ANL [12], CIEMAT [13,14], LNE-LNHB [15,16] and PTB [17]. New set-ups have recently been constructed in TAEK (Turkey) and NPL (UK), inspired by the IRMM model.…”
Section: Metrologiamentioning
confidence: 99%
“…IRMM uses a segmented design with source chamber, distance tube and diaphragm fitting together on smoothly connecting flanges. The distance between diaphragm and a reference plate in the source holder can be measured directly or calculated from the sum of the heights of the individual components with an accuracy of about (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) µm. The distance seems unaffected by vacuum pumping.…”
Section: Chamber and Spacersmentioning
confidence: 99%
See 2 more Smart Citations