2016
DOI: 10.1103/physrevx.6.011013
|View full text |Cite
|
Sign up to set email alerts
|

Precision Electron-Beam Polarimetry at 1 GeV Using Diamond Microstrip Detectors

Abstract: We report on the highest precision yet achieved in the measurement of the polarization of a lowenergy, O(1 GeV), continuous wave (CW) electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond microstrip detector which was able to capture most of the spectrum of scattered electrons. The data analysis te… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
37
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 33 publications
(37 citation statements)
references
References 39 publications
0
37
0
Order By: Relevance
“…One can also use an optical polarimetry scheme where polarized electrons excite atomic target to high order states and then radiate circularly polarized fluorescence 43 . By using these methods, the variation of the beam spin polarization [44][45][46][47] in the level of 10 −2 can be measured. However in our scheme the spin variation is in the 10 −4 level, a higher resolution spin detector should be used.…”
Section: Effects Of the Probe Beam's Energymentioning
confidence: 99%
“…One can also use an optical polarimetry scheme where polarized electrons excite atomic target to high order states and then radiate circularly polarized fluorescence 43 . By using these methods, the variation of the beam spin polarization [44][45][46][47] in the level of 10 −2 can be measured. However in our scheme the spin variation is in the 10 −4 level, a higher resolution spin detector should be used.…”
Section: Effects Of the Probe Beam's Energymentioning
confidence: 99%
“…Details on the Compton polarimeter can be found in Ref. [48,50,51]. The results discussed here are from the electron detector only and were collected during the period between November, 2011 and May, 2012.…”
Section: The Hall C Compton Polarimetermentioning
confidence: 99%
“…The measured asymmetry was built from these yields as described in Ref. [48,51]. A statistical precision of < 1% per hour was routinely achieved.…”
Section: The Hall C Compton Polarimetermentioning
confidence: 99%
See 2 more Smart Citations