2003
DOI: 10.1016/s0009-8981(03)00163-3
|View full text |Cite
|
Sign up to set email alerts
|

Precision and long-term stability of capillary electrophoresis measurement of serum protein zones

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…They also found that CE had excellent within and between capillary precision of 0.6-3.3% (N = 10) and 1.8-4.5% (N = 120), respectively. The long-term reproducibility of Paragon 2000 has recently been confirmed in a study by Luraschi et al [41]. They found that the intercapillary and interinstrument precision over a 1 year period was less than 3.1% and a maximum QC imprecision of less than 6.1%.…”
Section: Serum Proteinsmentioning
confidence: 76%
See 1 more Smart Citation
“…They also found that CE had excellent within and between capillary precision of 0.6-3.3% (N = 10) and 1.8-4.5% (N = 120), respectively. The long-term reproducibility of Paragon 2000 has recently been confirmed in a study by Luraschi et al [41]. They found that the intercapillary and interinstrument precision over a 1 year period was less than 3.1% and a maximum QC imprecision of less than 6.1%.…”
Section: Serum Proteinsmentioning
confidence: 76%
“…1 and an overview of the technical details of the two instruments can be found in a review by Bossuyt [30]. Numerous papers have been written on the comparison of single capillary research [31][32][33][34][35][36][37][38][39] or commercial CZE instruments [40][41][42][43][44][45][46][47][48][49][50][51][52][53][54] with AGE or CAE. Jenkins et al [31][32][33] were the first to describe the comparison of CE with AGE using a large number of patient samples (N = 6500).…”
Section: Serum Proteinsmentioning
confidence: 99%
“…The instruments were fed the total protein values of the assayed sera, for automatic calculation of the zones' protein mass concentration, in g/L. Overall imprecision of CZE measurements of a-1-globulin, from longterm evaluation of system's stability (as monthly CV%) was in the interval 2.0%-8.4% (mean 5.2%) [15]. Immunonephelometric measurements of AAT, AAG and apolipoprotein A-I (ApoA) were carried out with an Immage kinetic immunonephelometer (Beckman Coulter).…”
Section: Methodsmentioning
confidence: 99%
“…Through the analysis of serum proteins, CZE could identify inflammation, nephrotic syndrome, bisalbuminemia, and a 1 -antitrypsin deficiency [193]. Quality control was performed extensively in CZE [194,195]. The method was found stable over 1-year period [195], and showed higher sensitivity (but lower specificity) than gel electrophoresis [193,196].…”
Section: Proteins In Bloodmentioning
confidence: 99%
“…Quality control was performed extensively in CZE [194,195]. The method was found stable over 1-year period [195], and showed higher sensitivity (but lower specificity) than gel electrophoresis [193,196]. Conflicting results between CZE and gel electrophoresis, and interferences of some substances including iodinated contrast agent and antibiotics, have also been observed [197].…”
Section: Proteins In Bloodmentioning
confidence: 99%