In this study, the precision of anatomical models and surgical guides pertaining to the knee joint, fabricated using the mSLA technique, was critically examined. The ITK-SNAP program was employed for the segmentation and reconstruction of knee joint anatomical structures, while surgical guide modelling was executed using the Siemens NX program. Subsequent fabrication of the models was accomplished with the Anycubic Photon Mono 4K MSLA 3D printer. An MCA II articulated arm equipped with a laser head, in conjunction with a TalyScan 150 profilometer, was utilized to gauge both the geometrical fidelity and surface roughness of the resulting models. Results indicated that the geometrical precision of these models remained within a tolerance of +/-0.3 mm. With regard to surface roughness, the Sa parameter was observed to lie between 2 and 2.5 µm.