2021
DOI: 10.1016/j.chroma.2021.462379
|View full text |Cite
|
Sign up to set email alerts
|

Precision analysis for the determination of steric mass action parameters using eight tobacco host cell proteins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 59 publications
0
6
0
Order By: Relevance
“…Often, modified versions of kinetic equations are used to reduce or increase the complexity of the mechanistic model e.g., as shown for the extended Langmuir model or exponentially modified Langmuir model ( Table 1 ). The SMA model is often used to describe sorption during ion exchange chromatography (IEX) and specifically accounts for the salt concentration, number of interacting ligands, and steric shielding of the ligand by bound proteins ( Parente and Wetlaufer 1986 ; Degerman et al, 2007 ; Osberghaus et al, 2012a ; Bernau et al, 2021 ). Currently, more than 15 isotherms are available for the description of chromatography modalities such as IEX and HIC ( Guo et al, 2020 ; Kumar and Lenhoff 2020 ; Saleh et al, 2021a ; Saleh et al, 2021b ; Kumar et al, 2021 ) as has been reviewed elsewhere ( Wang et al, 2016 ; Shekhawat and Rathore 2019 ).…”
Section: Modeling Approachesmentioning
confidence: 99%
See 4 more Smart Citations
“…Often, modified versions of kinetic equations are used to reduce or increase the complexity of the mechanistic model e.g., as shown for the extended Langmuir model or exponentially modified Langmuir model ( Table 1 ). The SMA model is often used to describe sorption during ion exchange chromatography (IEX) and specifically accounts for the salt concentration, number of interacting ligands, and steric shielding of the ligand by bound proteins ( Parente and Wetlaufer 1986 ; Degerman et al, 2007 ; Osberghaus et al, 2012a ; Bernau et al, 2021 ). Currently, more than 15 isotherms are available for the description of chromatography modalities such as IEX and HIC ( Guo et al, 2020 ; Kumar and Lenhoff 2020 ; Saleh et al, 2021a ; Saleh et al, 2021b ; Kumar et al, 2021 ) as has been reviewed elsewhere ( Wang et al, 2016 ; Shekhawat and Rathore 2019 ).…”
Section: Modeling Approachesmentioning
confidence: 99%
“…For example, an inaccurately determined column porosity can distorted the value calculated for the equilibrium constant when fitting a chromatography model to a given peak ( Heymann et al, 2022 ). Various methods have been proposed to determine equilibrium parameters ( Shukla et al, 1998 ; Osberghaus et al, 2012a ; Bernau et al, 2021 ) but the experimental determination of different types of liquid volumes in columns remains challenging, especially for packed-bed chromatography using porous, spherical beads as the stationary phase. These liquid volumes consist of inter-particle and intra-particle components ( Figure 1 ) ( Frank et al, 2022 ).…”
Section: Challenge Ii: Obtaining Experimental Data To Set Up the Modelmentioning
confidence: 99%
See 3 more Smart Citations