Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement

Abstract: The "gold standard" method to evaluate the mass balances achieved during dialysis for a given solute remains total dialysate collection (TDC). However, since handling over 100 liter volumes is unfeasible in our current dialysis units, alternative methods have been proposed, including urea kinetic modeling, partial dialysate collection (PDC) and more recently, monitoring of dialysate urea by on-line devices. Concerned by the complexity and costs generated by these devices, we aimed to adapt the simple "gold sta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
39
1
2

Year Published

2002
2002
2019
2019

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 60 publications
(44 citation statements)
references
References 15 publications
1
39
1
2
Order By: Relevance
“…Collection of the whole spent dialysate is very inconvenient. For this reason, collection of a representative fraction of spent hemodialysate, [16] continuous sampling of spent dialysate and total dialysate volume measurement, [16] or dialysate sampling at the beginning and at the end of dialysis session [17] were advised. However, these methods did not find a place in routine clinical practice.…”
Section: Discussionmentioning
confidence: 99%
“…Collection of the whole spent dialysate is very inconvenient. For this reason, collection of a representative fraction of spent hemodialysate, [16] continuous sampling of spent dialysate and total dialysate volume measurement, [16] or dialysate sampling at the beginning and at the end of dialysis session [17] were advised. However, these methods did not find a place in routine clinical practice.…”
Section: Discussionmentioning
confidence: 99%
“…The samples were then combined to determine mass transfer of phosphate and creatinine. This procedure has been validated in the literature [5,6]. …”
Section: Methodsmentioning
confidence: 99%
“…item S4). Additionally, continuous sampling of spent dialysate [21,22] using a reverse infusion pump (Perfusor Secura FT; B. Braun, Germany) was employed to measure urea, creatinine, β 2 M and phosphate excretion in the spent dialysate (online suppl. item S5).…”
Section: Methodsmentioning