2014
DOI: 10.1016/j.sab.2013.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Precise alignment of the collection fiber assisted by real-time plasma imaging in laser-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
53
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 76 publications
(54 citation statements)
references
References 24 publications
1
53
0
Order By: Relevance
“…The instrument used to provide the LIBS images has been described in [12] and [13] (laser source was a Nd:YAG emitting 8 ns pulses at 1064 nm with a 100 Hz repetition rate; laser energy was reduced at typically 1.5 mJ; laser pulses were focused onto the sample by a 15× magnification objective resulting in a crater size close to 8 µm). The spatial distributions of Mg and Sr were found to be rather similar in the external layer (Figure 8a and 8c).…”
Section: Photonic Methods and Resultsmentioning
confidence: 99%
“…The instrument used to provide the LIBS images has been described in [12] and [13] (laser source was a Nd:YAG emitting 8 ns pulses at 1064 nm with a 100 Hz repetition rate; laser energy was reduced at typically 1.5 mJ; laser pulses were focused onto the sample by a 15× magnification objective resulting in a crater size close to 8 µm). The spatial distributions of Mg and Sr were found to be rather similar in the external layer (Figure 8a and 8c).…”
Section: Photonic Methods and Resultsmentioning
confidence: 99%
“…It has already been described in details elsewhere [37] and only its main components are described in the following. The laser source was a Nd:YAG emitting 5 ns pulses at the fundamental wavelength (1064 nm) with a 10 Hz repetition rate.…”
Section: Libs Imagingmentioning
confidence: 99%
“…In addition, the vertical positioning of the sample was controlled by using a laser pointer focused obliquely on the sample surface. The position of the laser pointer on the sample surface, imaged by the CCD camera, is indeed a direct monitoring of the focusing distance [37]. Homemade software developed in the LabVIEW environment controlled the all system and allowed automated sequences to be set in order to scan the region of interest.…”
Section: Libs Imagingmentioning
confidence: 99%
“…and Motto-Ros et al, 28 the relationship between the spatial distribution of the plasma and the spectral intensities of several characteristic lines was established. The spatial distributions of aluminium atoms, aluminium ions, argon atoms and argon ions were described.…”
mentioning
confidence: 92%
“…It was proved that the precise alignment of the collection ber, assisted by real-time plasma imaging, is an effective method to control the shape of the plasma and to keep the collecting parameters consistent in the laboratory environment. 28 However, it is hard to change either the position of the samples or the position of the collecting system in on-line applications in the factory environment, because the production line is always xed and the probe designed for industrial application is too large to be accurately controlled in real time. 4 Ni et al 29 presented a spectral normalization method assisted by the synchronous image of the plasma.…”
mentioning
confidence: 99%