2018
DOI: 10.1111/joic.12490
|View full text |Cite
|
Sign up to set email alerts
|

Pre‐close technique of percutaneous closure for delayed hemostasis of large‐bore femoral sheaths

Abstract: Advancement of coronary interventions and portable hemodynamic device requires placement of large bore sheaths. Access for large caliber sheaths, its placement, maintenance, and hemostasis is very challenging and one of the key ailments for successful procedures. Traditional hemostasis method is manual compression, which is unattractive due to its own limitations and subsequent complications. Single closure device for sheath size larger than 8 French (Fr) is not available. We performed retrospective analysis o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(21 citation statements)
references
References 10 publications
(10 reference statements)
0
21
0
Order By: Relevance
“… 31 , 32 An Impella arteriotomy preclosure technique has also been described. 33 In addition, these patients were critically ill with multiple metabolic derangements, including hepatic dysfunction, which can contribute to coagulopathy. Moreover, patients frequently had chest trauma from cardiopulmonary resuscitation, were exposed to multiple antithrombotic agents, and may develop acquired Von Willebrand syndrome due to high blood shear forces caused by Impella CP.…”
Section: Discussionmentioning
confidence: 99%
“… 31 , 32 An Impella arteriotomy preclosure technique has also been described. 33 In addition, these patients were critically ill with multiple metabolic derangements, including hepatic dysfunction, which can contribute to coagulopathy. Moreover, patients frequently had chest trauma from cardiopulmonary resuscitation, were exposed to multiple antithrombotic agents, and may develop acquired Von Willebrand syndrome due to high blood shear forces caused by Impella CP.…”
Section: Discussionmentioning
confidence: 99%
“…We then proceeded to perform preclosure of the left common femoral artery. This technique has been previously described 3 . After successful preclosure and placement of the 14 F sheath, the Impella CP device (Abiomed) was successfully placed in the LV per the instructions for use.…”
Section: Techniquementioning
confidence: 99%
“…The 14 F sheath was removed, peeled away, and the repositioning sheath was placed without oozing. The perclose sutures were secured in place similar to the technique described by Lata et al 3 The patient did well overnight, including tolerating postprocedure hemodialysis. He underwent successful Impella (Abiomed) removal the following day in the Cath Lab utilizing the previously placed preclose sutures.…”
Section: Techniquementioning
confidence: 99%
“…1). Puncture site closure devices, including collagen plugs, percutaneous devices, and external compression devices, have become popular recently to prevent access-related complications [16][17][18] though concrete evidence regarding their benefits in reducing complications is still lacking.…”
Section: Complications Related To Vascular Accessmentioning
confidence: 99%