2022
DOI: 10.3390/s22031151
|View full text |Cite
|
Sign up to set email alerts
|

Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples

Abstract: A very simple, as well as sensitive and selective, sensing protocol was developed on a pre-anodized graphite pencil electrode surface coated using poly(thionine) (APGE/PTH). The poly(thionine) coated graphite pencil was then used for simultaneous sensing of 3-nitrophenol (3-NP) and 4-nitrophenol (4-NP). The poly(thionine) coated electrode exhibited an enhanced electrocatalytic property towards nitrophenol (3-NP and 4-NP) reduction. Redox peak potential and current of both nitrophenols were found well resolved … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 64 publications
(74 reference statements)
0
4
0
Order By: Relevance
“…All tested TiO 2 samples showed the reduction signals at the potential near À 0.03 V vs. Ag/AgCl in the presence of 3-NP, contrary to the blank experiments without 3-NP or at the glassy carbon electrode with 3-NP (Figure 5a). It is worth noting that, according to the literature, [75,76] two 3-NP reduction waves (formation of 3-hydroxyaminophenol and 3aminophenol) are located at ca. À 0.06 and À 0.65 V vs. Ag/ AgCl (pH = 7).…”
Section: Electrochemical Analysismentioning
confidence: 91%
“…All tested TiO 2 samples showed the reduction signals at the potential near À 0.03 V vs. Ag/AgCl in the presence of 3-NP, contrary to the blank experiments without 3-NP or at the glassy carbon electrode with 3-NP (Figure 5a). It is worth noting that, according to the literature, [75,76] two 3-NP reduction waves (formation of 3-hydroxyaminophenol and 3aminophenol) are located at ca. À 0.06 and À 0.65 V vs. Ag/ AgCl (pH = 7).…”
Section: Electrochemical Analysismentioning
confidence: 91%
“…This makes it a conducting material and suitable for use in electrodes. Pencil graphite electrodes have been used for the analysis of various nitroaromatics such as nitrobenzene, nitrophenols, and TNT. …”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, according to Bond et al PEGs generate smaller background current compared to GCEs, and noble metal electrodes [33]. Recently various modified PGEs or unmodified PGE-based sensing devices have been reported [31,[34][35][36][37]. For example, V. Kumar et al incorporated copper nanoparticles onto the PGE surface and applied the modified electrode for the detection of Adenine.…”
Section: Introductionmentioning
confidence: 99%