2014
DOI: 10.5414/atx0947
|View full text |Cite
|
Sign up to set email alerts
|

Praxisleitlinien Ergometrie

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
25
0
6

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(34 citation statements)
references
References 15 publications
1
25
0
6
Order By: Relevance
“…Only tests with correct HRPC presentation (no outliers or interruptions of HR recordings) and a HR max within 15% of the expected HR max calculated as 210-age were included in our analysis. The test protocol was uniform and independent from age, gender and performance and was applied according to the recommendations of the local Society of Cardiology (22). All ergometer tests started at 20 W and power was increased in uniform 20 W increments per minute up to exhaustion.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Only tests with correct HRPC presentation (no outliers or interruptions of HR recordings) and a HR max within 15% of the expected HR max calculated as 210-age were included in our analysis. The test protocol was uniform and independent from age, gender and performance and was applied according to the recommendations of the local Society of Cardiology (22). All ergometer tests started at 20 W and power was increased in uniform 20 W increments per minute up to exhaustion.…”
Section: Methodsmentioning
confidence: 99%
“…k-values were classified as downward deflection k+ (k > 0.1) (regular), linear k0 (−0.1 ≤ k ≤ 0.1) and upward deflection k-(k < −0.1) (atypical) (Figure 1). Furthermore, P max in percent of age predicted power (%P max ) was calculated using a standard equation (Table 1) from the local cardiological society (22). To assess the effect of performance on HR deflection and HR max we compared subjects with low (P low : 25%-quartile) and high (P high : 75%-quartile) performance (%P max ) within each age group.…”
Section: Methodsmentioning
confidence: 99%
“…The CPET was performed on a bicycle ergometer (Ergoselect 200, Ergoline, Germany) according to the current guidelines for exercise tests (28,29) at the end of CR. Patients aimed to achieve a consistent cadence of >60 revs/min in a sitting position.…”
Section: Cardiopulmonary Exercise Testmentioning
confidence: 99%
“…Exercise stress testing was performed as an incremental exercise on a cycle ergometer (Excalibur Sport, company LODE). The workload was increased every minute until exhaustion [19]. ECG and oxygen consumption were continuously recorded, blood pressure and lactate were measured every two minutes.…”
Section: Methodsmentioning
confidence: 99%
“…Step 2 consisted of a spiroergometry which was performed in a stepwise fashion [19]. Exercise stress testing was performed as an incremental exercise on a cycle ergometer (Excalibur Sport, company LODE).…”
Section: Methodsmentioning
confidence: 99%