2017
DOI: 10.1109/jsen.2017.2746748
|View full text |Cite
|
Sign up to set email alerts
|

Practical Implementation of Electrical Tomography in a Distributed System to Examine the Condition of Objects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
28
0
1

Year Published

2018
2018
2021
2021

Publication Types

Select...
9
1

Relationship

5
5

Authors

Journals

citations
Cited by 52 publications
(29 citation statements)
references
References 24 publications
0
28
0
1
Order By: Relevance
“…The first Electrical Capacitance Tomography (ECT) systems [120,113,158,79], Electrical Resistance Tomography (ERT) systems [33,32,147,127] as well as the Magnetic Induction (MI) [90,119] allowed to obtain only the rough evaluation of the process state because the information encoded in measurement data represents merely the fragment of the process which additionally was approximated into the cross-section surface through the sensor (2D ECT) [60,163,78,128,135]. This kind of imaging, however still commonly applied in many industrial applications [50,66,67,104,75,65], occurs to be insufficient from the process control point of view.…”
Section: Electrical Tomographymentioning
confidence: 99%
“…The first Electrical Capacitance Tomography (ECT) systems [120,113,158,79], Electrical Resistance Tomography (ERT) systems [33,32,147,127] as well as the Magnetic Induction (MI) [90,119] allowed to obtain only the rough evaluation of the process state because the information encoded in measurement data represents merely the fragment of the process which additionally was approximated into the cross-section surface through the sensor (2D ECT) [60,163,78,128,135]. This kind of imaging, however still commonly applied in many industrial applications [50,66,67,104,75,65], occurs to be insufficient from the process control point of view.…”
Section: Electrical Tomographymentioning
confidence: 99%
“…Building porous materials (eg bricks or concrete), both natural and made, has pores (like a sponge). The data collection system collects the measured voltage from the electrode and then processes the data [1][2][3][5][6][7][8][9][10][11][13][14][15][28][29][30][31][32][33]. Figure 1 presents the model of a hybrid tomography system.…”
Section: Introductionmentioning
confidence: 99%
“…One of the means of ensuring the safety of flood-endangered areas near the flotation tailings landfills and rivers is to raise the flood embankments [18]. Considering the insufficient filtration capacity of the embankment, the high water level may cause leaks, which results in partial or complete destruction of the hydrotechnical building [19].…”
Section: Introductionmentioning
confidence: 99%