1978
DOI: 10.1016/s0021-9673(00)91170-1
|View full text |Cite
|
Sign up to set email alerts
|

Practical experience with a microwave plasma detector limits of measurement and examples of applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
1

Year Published

1984
1984
1999
1999

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(16 citation statements)
references
References 2 publications
1
14
1
Order By: Relevance
“…If the analyte did contain oxygen at measurable levels, the negative peak was preceded by a positive inflection in the chromatogram. This effect was documented in several publications (Brenner 1978;Slatkavitz, Uden, and Barnes 1986) and was observed in our laboratory. Thus, we were not able to obtain sufficient background reduction for oxygen or nitrogen to enable use of the GC-MIP for these elements.…”
Section: Identification Of Background Sourcessupporting
confidence: 81%
See 1 more Smart Citation
“…If the analyte did contain oxygen at measurable levels, the negative peak was preceded by a positive inflection in the chromatogram. This effect was documented in several publications (Brenner 1978;Slatkavitz, Uden, and Barnes 1986) and was observed in our laboratory. Thus, we were not able to obtain sufficient background reduction for oxygen or nitrogen to enable use of the GC-MIP for these elements.…”
Section: Identification Of Background Sourcessupporting
confidence: 81%
“…In its initial stages, most of the work with the GC-MIP used packed columns and dealt with standard compounds in single-element mode. Later studies incorporated the use of capillary columns (e.g., Quimby et al 1980;Wasik and Schwarz 1980;Hanie et al 1981;Estes, Uden, and Barnes !981) or polychromators (e.g., Bonnekessel and Klier 1978;Brenner 1978;Windsor and Denton 1979;Eckhoff, Ridgway, and Caruso 1983). The plasma portion of the GC-MIP technique has also evolved since its introduction.…”
Section: Introductionmentioning
confidence: 99%
“…The actual coupling procedure is described in detail in the literature (4). A siliconized glass column (2 mm i.d., 2 m long) packed with 3 % SE 30 on Chromosorb Q 100-120 mesh was used.…”
Section: Gas Chromatography/microwave Plasma Detector (Gc/mpd)mentioning
confidence: 99%
“…The performance of a commercial GC-MIP instrument using a multi-channel polychromator spectrometer was reported by Brenner [60]. For a helium plasma at 0.5-3 torr with oxygen or nitrogen scavenger gas, detection limits ranged from 0.02 ng/s for bromine to 4 ne/s for oxygen.…”
Section: Analytical Gc Applicationsmentioning
confidence: 95%