2023
DOI: 10.1016/j.ejmp.2023.102568
|View full text |Cite
|
Sign up to set email alerts
|

Practical and technical key challenges in head and neck adaptive radiotherapy: The GORTEC point of view

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 159 publications
0
5
0
Order By: Relevance
“…Meanwhile, there was no significant difference in EUD for the spinal canal and the plexus brachialis, probably because the primary focus of IGRT was laid upon reproducible positioning of the vertebrae. There exist different modalities of 3-dimensional imaging, which allow adaptive radiation therapy by calculating the spatial dose, kV-CBCT, MV-CBCT or MR-guided [ 25 ], each of which has its limitations and challenges. An alternative to CBCT-based ART is MR-guided online adaptive radiotherapy (MRgART).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Meanwhile, there was no significant difference in EUD for the spinal canal and the plexus brachialis, probably because the primary focus of IGRT was laid upon reproducible positioning of the vertebrae. There exist different modalities of 3-dimensional imaging, which allow adaptive radiation therapy by calculating the spatial dose, kV-CBCT, MV-CBCT or MR-guided [ 25 ], each of which has its limitations and challenges. An alternative to CBCT-based ART is MR-guided online adaptive radiotherapy (MRgART).…”
Section: Discussionmentioning
confidence: 99%
“…NCT04883281, NCT01874587, NCT04901234, NCT04172753, NCT03972072, https://www.clinicaltrials.gov/ ]. Preceding, retrospective dosimetric studies report a beneficial dose distribution of ART compared to classical IGRT [ 14 17 , 23 , 25 , 43 ]. A single prospective, randomized phase 3-trial published so far on weekly, offline plan adaptation showed a rather sober picture without a clear clinical benefit of offline ART compared to standard IGRT for the primary endpoint, sparing the parotid glands [ 24 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, utilizing kV-CBCT images for patient position alignment within the treatment room can effectively address these limitations. However, the direct application of kV-CBCT images for re-planning is constrained due to various factors, including inconsistent CT numbers, image quality issues related to scattered artifacts and noise, as well as limitations in the field-of-view [7][8][9]. Therefore, prior to utilizing kV-CBCT in ART, it is necessary to perform kV-CBCT correction.…”
Section: Introductionmentioning
confidence: 99%
“…In the existing literature, several techniques have been proposed for performing kV-CBCT dose calculation [8][9][10]. These methods encompass (1) the establishment of a calibration curve that correlates Hounsfield units (HU) with electron densities; this curve can be defined using either an adapted phantom or patient kV-CBCT images.…”
Section: Introductionmentioning
confidence: 99%