Eurocon 2013 2013
DOI: 10.1109/eurocon.2013.6625185
|View full text |Cite
|
Sign up to set email alerts
|

Power transformer main insulation design improvement using BEM and FEM

Abstract: Insulation system is one of the most important parts of power transformer. Theoretical background for insulation design is given, which includes explanation of dielectric properties of main insulation materials, their withstand to breakdown voltage, their verification by dielectric tests, and statistical data based theory for breakdown probability. Two known numerical methods (BEM and FEM) for calculation of electric field are used and for each numerical method an appropriate model of transformer is made. Safe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 8 publications
(8 reference statements)
0
8
0
Order By: Relevance
“…The volume of one turn of the primary winding is 7.068 × 10 À3 m 3 . The total volume of primary winding for 83 number of turns is 0.021,204 m 3 . The volume of one turn of the secondary winding is 6.498 × 10 À3 m 3 .…”
Section: Range Of Parametersmentioning
confidence: 99%
“…The volume of one turn of the primary winding is 7.068 × 10 À3 m 3 . The total volume of primary winding for 83 number of turns is 0.021,204 m 3 . The volume of one turn of the secondary winding is 6.498 × 10 À3 m 3 .…”
Section: Range Of Parametersmentioning
confidence: 99%
“…For each type of test, amount of voltage and time of test are regulated by the standard. For instance, separate source AC duration is one minute, and induced tests may last from twenty minutes to one hour (Mladen M., et al, 2013).…”
Section: Dielectric Testsmentioning
confidence: 99%
“…The insulation system is one of the important parts of a transformer, since its malfunctioning leads to transformer failure. The good insulation structure of a distribution transformer determines that a transformer normally operating during transformers lifetime (Mladen M., et al, 2013). In spite of the improvements done on the insulation materials used in transformer had enabled higher withstand voltages, engineers try to find new design rules to catch up with ever demanding task for increasing the profit and reduce the cost.…”
Section: General Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Most of the power transformers in current use are oil-immersed power transformers [4]. Many studies tended to improve the insulation materials used in the high voltage devices in order to withstand higher voltages, yet studies and researches are progressing in order to find new insulation designs, in order to satisfy the increasing demand for the electrical energy, maximize the profit with minimum cost [5], [6]. A transformers are exposed to certain conditions during its normal operation while being in service, such as impulse overvoltages, or lighting impulse during sever weather conditions, therefor, certain tests that simulate these conditions which a transformer must be subjected to them in order to fulfill that a transformer can withstand such conditions.…”
Section: Introductionmentioning
confidence: 99%