2014 49th International Universities Power Engineering Conference (UPEC) 2014
DOI: 10.1109/upec.2014.6934703
|View full text |Cite
|
Sign up to set email alerts
|

Power system stability enhancement of the future GB transmission system using HVDC link

Abstract: Bulk Abstract-As a consequence of the fast development of renewable energy sources in the UK, higher transmission capacity will be required to integrate potentially large volumes of wind generation in the future. Also, over the next decade, maintaining the transmission system security and stability will become more difficult. A major increase in the application of HVDC transmission technology and the deployment of series compensation within the existing AC transmission system is expected to provide the require… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…Table 1 summarizes the total number of works included in the database. In total, 181 papers were found using the aforementioned search criteria ( [44], [45], [49], [55], [56], [57], [58], [59], [60], [61], [62], [64], [65], [66], [67], [68], [73], [78], [80], [81], [90], [96], [104], [105], [106], [107], [108], [109], [110], [111], [112], [113], [114], [115], [116], [117], [118], [119], [120], [121], [122], [123], [124], [125], [126], [127], [128], [129],…”
Section: Classification Of Control Strategiesmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 1 summarizes the total number of works included in the database. In total, 181 papers were found using the aforementioned search criteria ( [44], [45], [49], [55], [56], [57], [58], [59], [60], [61], [62], [64], [65], [66], [67], [68], [73], [78], [80], [81], [90], [96], [104], [105], [106], [107], [108], [109], [110], [111], [112], [113], [114], [115], [116], [117], [118], [119], [120], [121], [122], [123], [124], [125], [126], [127], [128], [129],…”
Section: Classification Of Control Strategiesmentioning
confidence: 99%
“…Hence, plenty of control strategies have been developed with HVDC-links as main controllable devices, especially for addressing transient rotor-angle stability and inter-area oscillations issues. Most works rely purely on HVDC-links, as in [49], [106], [107], [115], [121], [133], [138], [142], [154], [155], [159], [161], [175], [182], [187], [213], [221], [222], [238], and [254]. However, in practical large-scale interconnected systems, there are usually various interarea oscillation modes with various oscillation shapes that act together and endanger the stable and secure operation of power systems.…”
Section: ) Hvdc-linkmentioning
confidence: 99%
See 1 more Smart Citation
“…Damping ratio ξ is a quantitative measure that relates the oscillation decaying following after a disturbance. In inter-area oscillation damping studies, the mode is called "critical" which should be usually suppressed by a compensator such as FACTS device, if its damping ratio is less than 5 % [20], [21], [22]. Table 2 lists the oscillation frequency and the damping ratio of each case study.…”
Section: Quantitative Comparison Of Case Studiesmentioning
confidence: 99%