2021
DOI: 10.1515/ijeeps-2021-0040
|View full text |Cite
|
Sign up to set email alerts
|

Power quality improvement in a photovoltaic based microgrid integrated network using multilevel inverter

Abstract: The increasing use of power electronics devices as well as the integration of renewable source-based microgrids (MG) has seriously affects the power quality (PQ) of the three-phase power system. Therefore, for the improvement of PQ, it is required to reduce the total harmonics distortion (THD) in the utility network. In this work, the improvement of PQ is discussed in a photovoltaic (PV) based MG integrated three-phase system using a three-level H-bridge (3LHB) multilevel inverter (MI). The MI is used for comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 42 publications
0
7
0
Order By: Relevance
“…Das et al [ 29 ] suggested an improvement of PQ is discussed in a PV‐ based MG integrated three‐phase system using a three‐level H‐bridge (3LHB) multilevel inverter (MI). However the multilevel inverter is more expensive and the model is bulky.…”
Section: Related Workmentioning
confidence: 99%
“…Das et al [ 29 ] suggested an improvement of PQ is discussed in a PV‐ based MG integrated three‐phase system using a three‐level H‐bridge (3LHB) multilevel inverter (MI). However the multilevel inverter is more expensive and the model is bulky.…”
Section: Related Workmentioning
confidence: 99%
“…When the converter operates under ideal conditions, considering the phase change process, the 6kth characteristic harmonic voltage will be modulated on the AC side to be generated. For the system side, even if the corresponding 6kth ripple current generated by the 6kth characteristic harmonic voltage on the AC side is considered, the AC current and the 6kth ripple current are modulated by the switching function at the same time [4] . If the system voltage does not satisfy the ideal conditions and a non-characteristic harmonic voltage appears on the AC side, the corresponding noncharacteristic harmonic current will appear on the AC side after modulation by the switching function [5].…”
Section: Multi-objective Voltage Reactive Power Harmonic Optimization...mentioning
confidence: 99%
“…As an important issue, power quality of hybrid energy systems has been studied in the previous studies [16][17][18]. In [19], power quality of a hybrid power system has been improved using fuzzy logic-based compensation.…”
Section: Introductionmentioning
confidence: 99%