2012 IEEE Student Conference on Research and Development (SCOReD) 2012
DOI: 10.1109/scored.2012.6518600
|View full text |Cite
|
Sign up to set email alerts
|

Power quality impact of grid-connected photovoltaic generation system in distribution networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
44
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 59 publications
(46 citation statements)
references
References 10 publications
2
44
0
Order By: Relevance
“…SIMULATION AND RESULTS To verify the applicability of the GA in optimal placement and sizing D-STATCOM problems, the proposed method is applied on the modified IEEE 16-bus test system shown in Fig. 3 [12]. The system is balanced and composed of several linear and non-linear loads with a total power of 2.73 MVA.…”
Section: B Application Of Fa In Solving the Optimal Location And Sizmentioning
confidence: 99%
“…SIMULATION AND RESULTS To verify the applicability of the GA in optimal placement and sizing D-STATCOM problems, the proposed method is applied on the modified IEEE 16-bus test system shown in Fig. 3 [12]. The system is balanced and composed of several linear and non-linear loads with a total power of 2.73 MVA.…”
Section: B Application Of Fa In Solving the Optimal Location And Sizmentioning
confidence: 99%
“…Table 1 lists some of these studies; several of them include THD/IHD analysis through on-site measurements during several time periods. PV system integration in low-voltage (LV) and medium-voltage (MV) networks can increase the Vrms and decrease the THDV at the PCC [9][10][11][16][17][18][19]21]; this effect seems to be more noticeable for higher PV power injections.…”
Section: Introductionmentioning
confidence: 99%
“…These generations can be coupled in common DCbus or ACbus structure at each bus in EPS to become a microgrid. This microgrid can be operated in two ways: generating power from generations to EPS directly or being dispatched by any scenario as requirement of dispatchers [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…In the first way, power generating to the grid varies continuously corresponding to the variation solar irradiance and wind speed [1]. This big disadvantage can be made difficult to dispatch power flow in whole EPS due to having to be absorbed big amount of power in daytime and or shortage a big amount of power in night-time.…”
Section: Introductionmentioning
confidence: 99%