Power Quality Disturbances Assessment during Unintentional Islanding Scenarios. A Contribution to Voltage Sag Studies

Abstract: This paper presents a novel voltage sag topology that occurs during an unintentional islanding operation (IO) within a distribution network (DN) due to large induction motors (IMs). When a fault occurs, following the circuit breaker (CB) fault clearing, transiently, the IMs act as generators due to their remanent kinetic energy until the CB reclosing takes place. This paper primarily contributes to voltage sag characterization. Therefore, this novel topology is presented, analytically modelled and further vali… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 59 publications
(64 reference statements)
0
9
0
Order By: Relevance
“…The work [10] "Power Quality Disturbances Assessment during Unintentional Islanding Scenarios" by A. Serrano et al presents a novel voltage sag topology that occurs during an unintentional islanding operation. This is precisely the value of the paper, because it analyzed and documented a particular and very common case in the industry practice: the effects of large induction motors in islanding cases.…”
Section: A Short Review Of the Contributions In This Issuementioning
confidence: 99%
“…The work [10] "Power Quality Disturbances Assessment during Unintentional Islanding Scenarios" by A. Serrano et al presents a novel voltage sag topology that occurs during an unintentional islanding operation. This is precisely the value of the paper, because it analyzed and documented a particular and very common case in the industry practice: the effects of large induction motors in islanding cases.…”
Section: A Short Review Of the Contributions In This Issuementioning
confidence: 99%
“…DG can use different grid monitoring techniques for obtaining online estimates of the grid parameters and stay synchronized with the grid. However, the performance of these estimators is perturbed by faults in the grid, such as voltage sags and swells, which in turn implies a worse DG performance of DG when injecting power to the grid [5][6][7][8][9][10][11][12][13][14][15]. Therefore, during grid faults, a fast and accurate detection of the grid voltage parameters is essential to keep a high quality in the DG's operation [6].…”
Section: Introductionmentioning
confidence: 99%
“…Energies 2022, 15, x FOR PEER REVIEW 2 of 16 below 90% of the specified voltage for more than a few cycles, such equipment can trip. Furthermore, voltage sags are caused by faults that occur hundreds of kilometers away [5][6][7][8]. Even if the voltage sag is not as severe as an interruption, the overall damage caused by sags is larger than that caused by interruptions since there are much more voltage sags than interruptions.…”
Section: Introductionmentioning
confidence: 99%