2019
DOI: 10.1109/tsg.2019.2901193
|View full text |Cite
|
Sign up to set email alerts
|

Power Flow Control of Interconnected AC–DC Microgrids in Grid-Connected Hybrid Microgrids Using Modified UIPC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
39
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(39 citation statements)
references
References 30 publications
0
39
0
Order By: Relevance
“…The performance of the proposed FLS-based EMS was compared with the selfadaptive controller and mixed-integer linear programming (MILP) scheduling; however, the operating cost of the proposed method was higher than other methods due to the high computation. Similar work was addressed in [10], where the FLS controlled agent-based electric vehicle (EV) charging-discharging was reported without discussion about the computation burden. In [11], a modified unified interphase power controller, for both DC-link and AC-link microgrid, was implemented, where the power flow control was demonstrated without discussing the power losses in the different stages.…”
Section: Introductionmentioning
confidence: 85%
“…The performance of the proposed FLS-based EMS was compared with the selfadaptive controller and mixed-integer linear programming (MILP) scheduling; however, the operating cost of the proposed method was higher than other methods due to the high computation. Similar work was addressed in [10], where the FLS controlled agent-based electric vehicle (EV) charging-discharging was reported without discussion about the computation burden. In [11], a modified unified interphase power controller, for both DC-link and AC-link microgrid, was implemented, where the power flow control was demonstrated without discussing the power losses in the different stages.…”
Section: Introductionmentioning
confidence: 85%
“…In [ 16 ], a voltage-booster scheme includes the DVR and high-temperature superconducting FCL (HTS-FCL) are designed and implemented to the doubly-fed induction generator (DFIG) for enhancing the fault-ride through (FRT) performance. In [ 17 ], the unified inter-phase power controller (UIPC) is used to control power flow in hybrid AC/DC micro-grid. In [ 18 ], a multi-step braking resistor is proposed to enhance the FRT performance of fixed-speed wind turbines.…”
Section: Introductionmentioning
confidence: 99%
“…The associate editor coordinating the review of this manuscript and approving it for publication was Yang Li . AC and DC microgrid. [3]. For example, a comprehensive analysis of renewable energy systems has been addressed using technology, economic and environmental factors variables [4].…”
Section: Introductionmentioning