Power factor correction of non-linear loads employing a single phase active power filter: control strategy, design methodology and experimentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
3

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(17 citation statements)
references
References 2 publications
0
14
0
3
Order By: Relevance
“…It has terms at the same frequencies as the input power as well as terms that vary at other grid-frequency harmonics. Due to the low bandwidth of the outer voltage loop, only the low-frequency terms in (9) are required for the control design. These low-frequency terms are derived by averaging (9) over one-half of the grid period d dt…”
Section: Appendix Small-signal Model Of the Outer Voltage Loopmentioning
confidence: 99%
See 1 more Smart Citation
“…It has terms at the same frequencies as the input power as well as terms that vary at other grid-frequency harmonics. Due to the low bandwidth of the outer voltage loop, only the low-frequency terms in (9) are required for the control design. These low-frequency terms are derived by averaging (9) over one-half of the grid period d dt…”
Section: Appendix Small-signal Model Of the Outer Voltage Loopmentioning
confidence: 99%
“…As an alternative, the indirect method generates a sinusoidal reference signal by means of grid-voltage sensing. In that case, the grid current is forced to follow this sinusoidal signal, and thus, the load harmonics are indirectly given by the APF inductor current [9]- [12]. The main advantages of this second approach are that only one low-bandwidth current sensor is required and faster transient response is obtained [12].…”
Section: Introductionmentioning
confidence: 99%
“…The controller can act in any convenient domain. The design of a current-regulated PWM system is described in [78] for closed loop control of grid currents in a single-phase APF. Control in the dq0 domain including feed-forward of the AC voltage is combined with SVM in [47].…”
Section: Current Regulated Pwmmentioning
confidence: 99%
“…It can limit harmonics to acceptable levels and can adapt itself in case of harmonic component alteration or even changes in the non-linear loads types. With a proper control strategy, a shunt APF can also compensate load reactive characteristics [7].…”
Section: Introductionmentioning