2022
DOI: 10.1109/tpel.2022.3149996
|View full text |Cite
|
Sign up to set email alerts
|

Power-Electronics-Based Mission Profile Emulation and Test for Electric Machine Drive System—Concepts, Features, and Challenges

Abstract: In the last decade, significant progress has been made in electrification, especially in the applications of electrical vehicles, renewable energies, and industry automations, which imposed much more complicated working conditions to electric machines as well as the drive converters. More advanced features, such as the control strategies, functionality, stability, and reliability of machine drive systems, need to be characterized and validated. Thus, there is an emerging need to accurately recreate the behavio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(7 citation statements)
references
References 85 publications
(103 reference statements)
0
4
0
Order By: Relevance
“…The objective function is used to calculate cost (i, x, w) as (x-w + 𝑙 𝑖 − 𝑔 𝑖 ), where the range of feasible x values from max (0, w − pc) to min (C, w + Pd). As a result, DP uses the recurrence shown in (7).…”
Section: Using Non-recursive Approachmentioning
confidence: 99%
See 2 more Smart Citations
“…The objective function is used to calculate cost (i, x, w) as (x-w + 𝑙 𝑖 − 𝑔 𝑖 ), where the range of feasible x values from max (0, w − pc) to min (C, w + Pd). As a result, DP uses the recurrence shown in (7).…”
Section: Using Non-recursive Approachmentioning
confidence: 99%
“…Similarly, some more scenarios are given. [5,10,12,14,15,15,14,12,10,5] and discharge as= [6,7,8,8,8,7,6,5,5,5], price as [2,3,5,7,10,13,15,17,18,20]. Before optimization the cost is = 620 after optimization the cost is 500.…”
Section: Using Non-recursive Approachmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, the penetration of distributed generations (DG) in the power grid keeps increasing dramatically. The microgrid has been proposed to integrate a number of DGs and loads on a more autonomous and smaller scale, where power electronic converters are adopted to manage the energy flows among the DGs and the loads [1][2][3][4][5]. The control schemes of converters are critical to the operation of the microgrid [6][7][8][9]; therefore, recreating the control behaviors in the AC microgrid is becoming essential for the testing, as well as teaching activities in this field.…”
Section: Introductionmentioning
confidence: 99%
“…The demand for power hardware in the loop simulation systems [22,23] and power electronics-based emulation systems [24][25][26] has gradually increased over the last years. In the past, CITCEA-UPC and teknoCEA have developed emulation systems based on specific requests from customers.…”
Section: Originmentioning