2017
DOI: 10.1541/ieejias.137.1
|View full text |Cite
|
Sign up to set email alerts
|

Power Converter with Parallel connected IGBTs for Ultra-High-Speed Elevators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…In addition, effects of DC‐side stray inductance are also reported; particularly, reducing variation of DC‐side stray inductance proves effective to suppress switching loss imbalance 9,10 . DC‐side stray inductance is caused by circuit structure, and bus bar designs were proposed to reduce inductance variation 11–14 . For example, a bus bar design with three parallel SiC power modules is described in literature; 12 specifically, slots are provided to reduce variation of stray inductance.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, effects of DC‐side stray inductance are also reported; particularly, reducing variation of DC‐side stray inductance proves effective to suppress switching loss imbalance 9,10 . DC‐side stray inductance is caused by circuit structure, and bus bar designs were proposed to reduce inductance variation 11–14 . For example, a bus bar design with three parallel SiC power modules is described in literature; 12 specifically, slots are provided to reduce variation of stray inductance.…”
Section: Introductionmentioning
confidence: 99%
“…For example, a bus bar design with three parallel SiC power modules is described in literature; 12 specifically, slots are provided to reduce variation of stray inductance. Literature 13 compares one‐phase bus bar designs in a three‐phase inverter with four parallel IGBT power modules. Thus, bus bar designs were proposed to reduce variation of stray inductance in parallel connection, but the issue of reducing stray inductance variation between the three phases has not been sufficiently explored.…”
Section: Introductionmentioning
confidence: 99%
“…9,10 DC-side stray inductance is caused by circuit structure, and bus bar designs were proposed to reduce inductance variation. [11][12][13][14] For example, a bus bar design with three parallel SiC power modules is described in literature; 12 specifically, slots are provided to reduce variation of stray inductance. Literature 13 compares one-phase bus bar designs in a three-phase inverter with four parallel IGBT power modules.…”
Section: Introductionmentioning
confidence: 99%