2014
DOI: 10.1016/j.ijepes.2013.12.009
|View full text |Cite
|
Sign up to set email alerts
|

Power control for grid connected applications based on the phase shifting of the inverter output voltage with respect to the grid voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0
3

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(26 citation statements)
references
References 18 publications
0
19
0
3
Order By: Relevance
“…These conditions change from the grid reference values such that the circuit breaker (CB) connected between the grid and the point of common coupling (PCC) clears the fault during islanding mode. Meanwhile, DG still supplies power to the local load if the CB cannot open the circuit [5]. Voltage shutdown, equipment failure, and short-circuit conditions cause an unpredictable interruption of the grid, and these abnormal conditions cause islanding operation in a PV system [6].…”
Section: Introductionmentioning
confidence: 99%
“…These conditions change from the grid reference values such that the circuit breaker (CB) connected between the grid and the point of common coupling (PCC) clears the fault during islanding mode. Meanwhile, DG still supplies power to the local load if the CB cannot open the circuit [5]. Voltage shutdown, equipment failure, and short-circuit conditions cause an unpredictable interruption of the grid, and these abnormal conditions cause islanding operation in a PV system [6].…”
Section: Introductionmentioning
confidence: 99%
“…In current control mode, the aim is to regulate the current that the inverter supplies into the network [5]. In voltage control mode, it is significant that the inverter generates a proper voltage waveform wherethe voltage must be kept with fixed amplitudeand fixed frequency, irrespective of the load types [18].…”
Section: Stabilitymentioning
confidence: 99%
“…The harmonics seems to be the main power quality issue [5]. Harmonics lead to equipment overheating, increasing of losses, and waveforms distortion [6].…”
Section: Introductionmentioning
confidence: 99%
“…• 22 trabalhos têm o objetivo específico de modelar inversores com a funcionalidade de compensação de reativos incorporada e demonstrar sua viabilidade técnica (HASSAINE et al, 2014;CHANG et al, 2014;RESHMA;RAJESH, 2013;MARTI et al, 2013;BELAIDI et al, 2013;NOROOZIAN;GHAREHPETIAN, 2013;LI et al, 2012;HAMZAOUI;BOUCHAFAA;HADJAMMAR, 2011;TURITSYN et al, 2011;LIU et al, 2011;SEO et al, 2009;ALBUQUERQUE et al, 2010;CAGNANO et al, 2011;TSENGENES;ADAMIDIS, 2011;TURITSYN et al, 2010;GHARAKHANY;MOHAMADIAN;VARJANI, 2009;CHUNLING et al, 2009;HAMROUNI;JRAIDI;CHÉRIF, 2008;HASSAINE et al, 2009;LIBO;ZHENGMING;JIANZHENG, 2007;YU;PAN;XIANG, 2005;BARBOSA et al, 1998;KIM;YOO;SONG, 1996);…”
Section: Síntese Da Revisão Bibliográficaunclassified
“…• desses 22, 13 têm como base metodológica exclusivamente simulações computadorizadas e apenas 8 apresentam resultados experimentais (CHANG et al, 2014;HASSAINE et al, 2014;LIU et al, 2011;RESHMA;RAJESH, 2013;HASSAINE et al, 2009;LIBO;ZHENGMING;JIANZHENG, 2007;KIM;YOO;SONG, 1996;BARBOSA et al, 1998), ainda que os inversores construídos fossem protótipos laboratoriais de, no máximo, 600 W.…”
Section: Síntese Da Revisão Bibliográficaunclassified