2005
DOI: 10.1002/ceat.200407160
|View full text |Cite
|
Sign up to set email alerts
|

Power Consumption in Dual Impeller Gas-Liquid Contactors: Impeller Spacing, Gas Flow Rate, and Viscosity Effects

Abstract: The dependence of power consumption on impeller spacing, and also in relation to gas flow rate and viscosity, in unaerated and aerated gas-liquid contactors agitated by dual Rushton-and by dual pitched blade turbines was comparatively studied. In tap water the two Rushton impellers acted independently for spacings greater than DH = 1.65d, while in glycerol solutions the impellers acted independently on reaching an impeller spacing equal to 1.20d; the corresponding values for the two pitched blade impellers wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 13 publications
(5 reference statements)
0
2
0
2
Order By: Relevance
“…Independent behavior of impellers has been reported for pitched blade turbines in tap water as starting with a spacing of 1.55d, while for two Rushton turbines it has been reported to start at a greater spacing of 1.65d [30,31,34]. For small gas flow rates, a sharp increase in Po is reported for dual Rushton turbines for spacing in the range of 0.6 to 0.8d, which is much smaller for higher gas flow rates [34]. For a dual pitched blade configuration, the effect of impeller spacing on power consumption is reportedly smaller in the flooded regime than for a dual Rushton configuration.…”
Section: Ref Remarksmentioning
confidence: 99%
See 1 more Smart Citation
“…Independent behavior of impellers has been reported for pitched blade turbines in tap water as starting with a spacing of 1.55d, while for two Rushton turbines it has been reported to start at a greater spacing of 1.65d [30,31,34]. For small gas flow rates, a sharp increase in Po is reported for dual Rushton turbines for spacing in the range of 0.6 to 0.8d, which is much smaller for higher gas flow rates [34]. For a dual pitched blade configuration, the effect of impeller spacing on power consumption is reportedly smaller in the flooded regime than for a dual Rushton configuration.…”
Section: Ref Remarksmentioning
confidence: 99%
“…For a dual pitched blade configuration, the effect of impeller spacing on power consumption is reportedly smaller in the flooded regime than for a dual Rushton configuration. However, a dual pitched blade configuration already starts acting independently at a spacing of 0.45d for high gas flow rates [34].…”
Section: Ref Remarksmentioning
confidence: 99%
“…Οι χαρακτηριστικοί αριθμοί Froude στην μετάβαση στην πλήρη διασπορά συναρτήσει εκείνων στην μετάβαση στην πλημμύριση για δύο διαμέτρους προωθητήρα, d=0.33D και d=0.49D [45].…”
Section: σχήμα 92unclassified
“…Παράλληλα, είναι αξιοσημείωτο το γεγονός ότι στην πλημμύριση το σύστημα ανάδευσης δεν μπορεί να αξιοποιήσει την ισχύ που καταναλώνει. Αυτό προκύπτει και από το Σχήμα 7.2 που ακολουθεί, το οποίο αναφέρεται σε σύστημα με διπλούς προωθητήρες Rushton και διάμετρο d=0.52D[45]. Σύμφωνα με τη βιβλιογραφία[37,40,41,42], τα συστήματα με διπλούς προωθητήρες δεν διαφέρουν ως προς τα χαρακτηριστικά μετάβασης στις διάφορες καταστάσεις διασποράς.…”
unclassified