Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2019
DOI: 10.1016/j.powtec.2019.05.065
|View full text |Cite
|
Sign up to set email alerts
|

Power consumption and gas–liquid mass transfer in a hot-sparged three-phase stirred reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 61 publications
0
4
0
Order By: Relevance
“…A DO probe (LeiCi DO JPSJ-605, Shanghai REX Sensor Technology Co., China) was used to measure the concentration of the dissolved oxygen, and the data were recorded by a computer. When the steady-state condition of equilibrium between the sulfite and oxygen dissolution is reached, the volumetric mass transfer coefficient ( k L a ′) is calculated by where Q s is the feed rate of the sulfite solution (m 3 ·s –1 ), C s is the concentration of sulfite in the feed solution (mol·m –3 ), V is the volume of the liquid in the aerated stirred tank (m 3 ), C Ai is the equilibrium concentration of oxygen at the gas–liquid interface (mol·m –3 ), and C As is the oxygen concentration measured in water at the steady state with the sulfite solution fed continuously (mol·m –3 ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A DO probe (LeiCi DO JPSJ-605, Shanghai REX Sensor Technology Co., China) was used to measure the concentration of the dissolved oxygen, and the data were recorded by a computer. When the steady-state condition of equilibrium between the sulfite and oxygen dissolution is reached, the volumetric mass transfer coefficient ( k L a ′) is calculated by where Q s is the feed rate of the sulfite solution (m 3 ·s –1 ), C s is the concentration of sulfite in the feed solution (mol·m –3 ), V is the volume of the liquid in the aerated stirred tank (m 3 ), C Ai is the equilibrium concentration of oxygen at the gas–liquid interface (mol·m –3 ), and C As is the oxygen concentration measured in water at the steady state with the sulfite solution fed continuously (mol·m –3 ).…”
Section: Methodsmentioning
confidence: 99%
“…A DO probe (LeiCi DO JPSJ-605, Shanghai REX Sensor Technology Co., China) was used to measure the concentration of the dissolved oxygen, and the data were recorded by a computer. When the steady-state condition of equilibrium between the sulfite and oxygen dissolution is reached, the volumetric mass transfer coefficient (k L a′) is calculated by 23…”
Section: Measurement Of the Volumetric Mass Transfer Coefficient (K L A)mentioning
confidence: 99%
“…The literature sources are diverse in opinion on the influence of solid particles on mass transfer. According to some of the published articles, k L a decreases in the presence of a solid phase in all conditions 4–7 or k L a decreases only at high concentrations of the solid phase or only at low impeller speeds 8. On the other hand, Gollakota et al 9 reported that k L a increases with the addition of solids.…”
Section: Introductionmentioning
confidence: 99%
“…Multiple authors also reported a small or no effect of the solid phase on the volumetric mass transfer coefficient 11–13. The increasing industrial importance of gas‐liquid‐solid systems has led to a focussed interest on the solid phase influence in such systems during the last couple of years 4, 14, 15. However, the mass transfer in gas‐liquid‐solid systems has not been fully described and understood, yet.…”
Section: Introductionmentioning
confidence: 99%