Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes

Abstract: This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10−7 to 10−2 mol L−1. The electrodes show Nerns… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…The obtained recovery and relative standard deviation values were compared with those obtained using a previously reported method (direct potentiometric determination of ketotifen at carbon paste electrode). 4 The recovery results of the reported method were in the range of 97.97% to 98.96% and the relative standard deviation was in the range of 0.74% to 1.73%. The obtained results were comparable with those obtained using the reported potentiometric method, confirming the validity of the proposed method for quality control assessment of ketotifen.…”
Section: Concentration Of Concentration Of Recovery Found Ketotifen Kmentioning
confidence: 84%
See 2 more Smart Citations
“…The obtained recovery and relative standard deviation values were compared with those obtained using a previously reported method (direct potentiometric determination of ketotifen at carbon paste electrode). 4 The recovery results of the reported method were in the range of 97.97% to 98.96% and the relative standard deviation was in the range of 0.74% to 1.73%. The obtained results were comparable with those obtained using the reported potentiometric method, confirming the validity of the proposed method for quality control assessment of ketotifen.…”
Section: Concentration Of Concentration Of Recovery Found Ketotifen Kmentioning
confidence: 84%
“…2−4,35−38 Therefore, the proposed sensor showed good sensing performance toward ketotifen oxidation in terms of limit of detection and sensitivity. [2] 4.60 Not reported 1.0 × 10 -5 to 1.0 × 10 -2 mol L -1 Not reported Flow nject on analys s PVC membrane electrode [3] 98.1 nmol L -1 Not reported 10 -7 to 10 -2 mol L -1 Not reported Potent ometr c Carbon paste electrode [4] 5.0 Not reported 5.0 × 10 -6 to 1.0 × 10 -2 mol L -1 Not reported Potent ometr c Coated graph te membrane [35] 0.7 nmol L -1 Not reported 5 × 10 -8 to 1 × 10 -6 mol L -1 Br tton-Rob nson bu er solut on (pH 11)…”
Section: Methods Validationmentioning
confidence: 99%
See 1 more Smart Citation
“…The therapeutic importance of the drug has prompted to develop various techniques for its assay in pharmaceuticals and body fluids. It is quantified by high performance liquid chromatography , high performance thin layer chromatography , liquid chromatography with mass spectrometry , spectrofluorimetry , direct differential pulse polarographic and adsorptive‐stripping voltammetry , UV spectrophotometry , potentiometric titration and coulumetric titration .…”
Section: Introductionmentioning
confidence: 99%
“…Potentiometry with ion selective electrodes (ISE) is one of the most important analytical tools capable of determining both organic and inorganic substances in medico-biological practice [12] . There is a constant progress in the number of electrodes capable of selectively identifying various drugs such as carbon paste electrodes (CPEs) [13] , [14] , [15] , [16] , [17] , [18] . Although the CPEs play an important role in the electrochemical analysis, the prepared pastes are soft and non-compactable and have to be packed into a special piston shaped holder with definite shape and size.…”
Section: Introductionmentioning
confidence: 99%