Potentiometric determination of chloride in vegetables by flow injection analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
2

Year Published

2000
2000
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 6 publications
0
1
0
2
Order By: Relevance
“…A two-line flow injection system with potentiometric detection was suggested by Lima et al (1996b) for the determination of chloride (Cl) in vegetables. The aqueous extracts were injected in a water carrier stream and next merged with a stream of potassium nitrate (KNO 3 ), methanol, HNO 3 , and sodium chloride (NaCl), with the purpose of adjusting thé ionic strength, reducing interferences from humic substances on the electrode membrane, and stabilizing the baseline.…”
Section: Anionic Speciesmentioning
confidence: 99%
“…A two-line flow injection system with potentiometric detection was suggested by Lima et al (1996b) for the determination of chloride (Cl) in vegetables. The aqueous extracts were injected in a water carrier stream and next merged with a stream of potassium nitrate (KNO 3 ), methanol, HNO 3 , and sodium chloride (NaCl), with the purpose of adjusting thé ionic strength, reducing interferences from humic substances on the electrode membrane, and stabilizing the baseline.…”
Section: Anionic Speciesmentioning
confidence: 99%
“…No caso da detecção por Uv/vis, os trabalhos descritos na literatura submetem as amostras a um tratamento prévio ou incorporam no sistema FIA unidades de diálise para eliminar vários tipos de interferentes (Leon e Centrich, 1991;Herrero et al, 1992;Morais et al, 1997). Dentro dos sistemas com detecção potenciométrica, uns efectuam a medição directa do cloreto, usando eléctrodos de configuração tubular, sem solução de referência interna, sensíveis ao anião cloreto (Ferreira et al, 1994a;Lima et al, 1996;Pérez-Olmos et al, 1997), enquanto outros utilizam as titulações FIA, usando um eléctrodo sensível ao catião prata, como indicador.…”
Section: Introductionunclassified
“…El FIA por detección potenciométrica se ha aplicado al análisis de cloruros en muchos tipos de aguas según la norma UNE EN ISO 15682: 2002 [102][103][104][105][106][107][108]. También se han usado para la detección del ion cloruro en vegetales [109], en alimentos [110], además de numerosas aplicaciones en el campo de la química clínica y bioanalítica [111].…”
Section: Métodos Electroanalíticos Para La Determinación De Clorurounclassified