2006
DOI: 10.1016/j.jpba.2006.04.022
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric assessment of Gram-negative bacterial permeabilization of tobramycin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…The proposed sensors were also compared with other electrochemical sensors from literature for determination of TOBRA [13,47], as shown in Table 2. This comparison shows that C-dots-CPE is superior to the reported aptamer-based gold sensor and β-Cyclodextrinbased sensor concerning the LOD, working pH range, lifetime, and intraday precision.…”
Section: Performance Characteristics Of the Bare-cpe Agnp-cpe And C-dots-cpementioning
confidence: 99%
See 1 more Smart Citation
“…The proposed sensors were also compared with other electrochemical sensors from literature for determination of TOBRA [13,47], as shown in Table 2. This comparison shows that C-dots-CPE is superior to the reported aptamer-based gold sensor and β-Cyclodextrinbased sensor concerning the LOD, working pH range, lifetime, and intraday precision.…”
Section: Performance Characteristics Of the Bare-cpe Agnp-cpe And C-dots-cpementioning
confidence: 99%
“…They are composed of graphite powder, an electroactive material, and a liquid binder, with the addition of nanoparticles as a new modification [9]. A literature survey revealed that electrochemical determination of TO-BRA was mainly performed through voltammetric sensors [10][11][12], and to date there is only one potentiometric sensor for the direct determination of TOBRA through a classical ion-selective electrode, where the sensing membrane was composed of β-cyclodextrin as ionophore for the evaluation of permeability of TOBRA in gram-negative bacteria [13]. Additionally, no carbon paste electrodes, whether bare or modified with nanoparticles, have been used for electrochemical determination of TOBRA.…”
Section: Introductionmentioning
confidence: 99%
“…Working on the determination of tobramycin with biosensor method has been started since 1997 with RNA aptamers [97], but after 9 years, the researchers were able to detect tobramycin with potentiometric measurements only in aqueous solutions [98].…”
Section: Tobramycinmentioning
confidence: 99%