Abstract: We investigate the potentials of digitally sampling scintillation pulses techniques for positron emission tomography (PET) in this paper, focusing on the determination of the event time. We have built, and continue building, a digital library of PET event waveforms generated with various combinations of photo-detectors and scintillator materials, with various crystal sizes. Events in this digital library are obtained at a high sampling of 20 GSps (Giga-samples per second) so that their waveforms are recorded w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
32
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 56 publications
(32 citation statements)
references
References 19 publications
0
32
0
Order By: Relevance
“…This result shows better time resolution than rv 300 ps FWHM[10] using the CFD under similar test setup.V. DISCUSSION AND SUMMARYWe have developed the prototype waveform sampling read out board using the DRS4 chip for a PET data acquisition.…”
mentioning
confidence: 63%
“…This result shows better time resolution than rv 300 ps FWHM[10] using the CFD under similar test setup.V. DISCUSSION AND SUMMARYWe have developed the prototype waveform sampling read out board using the DRS4 chip for a PET data acquisition.…”
mentioning
confidence: 63%
“…Due to noises in the previous pulse tail, linear areas of leading edges of pulses from the second and so on in a pileup were difficult to define, these reconstructed pulses contributed 922-ps timing resolution (down right). CFD [28], the delay was set as 1.6 ns and the attenuation coefficient was 0.2 in software CFD.…”
Section: B Timing Determinationmentioning
confidence: 99%
“…When more than one pulse was reconstructed from a pileup, the noises in the tail of a pulse would affect the accuracy of the linear fitting for the following pulse. In the DiSER method, the linear fitting was done on the middle part of the leading edge of the pulse, which has a better linearity [28] (as shown in Fig. 13).…”
Section: B Timing Determinationmentioning
confidence: 99%
See 1 more Smart Citation
“…M ULTI-VOLTAGE Threshold (MVT) [1], [2], [3] can digitize fast signals with reasonable cost, and has been used in PET detectors. The structure of MVT digitizer is described in Fig.…”
Section: Introductionmentioning