2013
DOI: 10.1016/j.ijrobp.2012.03.037
|View full text |Cite
|
Sign up to set email alerts
|

Potential of Hybrid Computational Phantoms for Retrospective Heart Dosimetry After Breast Radiation Therapy: A Feasibility Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 18 publications
1
6
0
Order By: Relevance
“…The difference between LAD dose and MHD is striking, but it can be explained by the fact that the LAD is located in the anterior region of the heart where it is exposed to the tangential fields used in left sided breast RT. Moreover, we observed a mean ratio Dmean LAD/MHD around 5, confirming prior findings [21]. However, the association between the MHD and delineated substructures, in particular the LAD mean dose, was not precise enough to predict with confidence individual patient dose as shown in Fig.…”
Section: Discussionsupporting
confidence: 89%
“…The difference between LAD dose and MHD is striking, but it can be explained by the fact that the LAD is located in the anterior region of the heart where it is exposed to the tangential fields used in left sided breast RT. Moreover, we observed a mean ratio Dmean LAD/MHD around 5, confirming prior findings [21]. However, the association between the MHD and delineated substructures, in particular the LAD mean dose, was not precise enough to predict with confidence individual patient dose as shown in Fig.…”
Section: Discussionsupporting
confidence: 89%
“…There have also been studies that instead chose to utilize dose measured to a water phantom, along with tumor location details from clinical records, to estimate the doses at the site of secondary tumor development [21]. Hybrid computational phantoms created from CT scans have been shown to be feasible for retrospective heart dosimetry following breast irradiation [26]. By also adding the use of Monte Carlo based dose calculations to pediatric hybrid phantoms, organ doses could be reconstructed to add further accuracy in future secondary cancer risk studies [27].…”
Section: Discussionmentioning
confidence: 99%
“…In this case, organ contouring must be redone so as to include all organs of interest. Also, to personalise the phantom to the patient, it is possible to mix the representative patient image with virtual modelled organs [34]. The modelled organ is voxelised and inserted into the representative patient RT-planning CT, hence producing a hybrid phantom.…”
Section: Imaging Of Patient Anatomymentioning
confidence: 99%