Potential of desorption electrospray ionization and paper spray ionization with high-resolution mass spectrometry for the screening of sports doping agents in urine

Abstract: In this work, desorption electrospray ionization and paper spray ionization both with high-resolution mass spectrometry (DESI-HRMS, PSI-HRMS) were explored for the fast and direct analysis of stimulants and diuretics in...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 48 publications
(65 reference statements)
0
4
0
Order By: Relevance
“…44 There is recent evidence of interest in the use of AIMS in antidoping, with ASAP being utilized for the analysis of anabolic steroids 45 and both DESI and PS-MS for the rapid detection of stimulants and diuretics in urine. 46 The development of ambient ionization techniques for the analysis of explosives also constitutes a notable proportion of applications in forensic science. The rapid detection and identification of explosives are of crucial importance to national security, and the development of techniques that could feasibly be installed in airports and used on-site at incident scenes are of particular interest.…”
Section: Kim Et Al Used Sfpesi For the Rapid Detection Of Cocaine Met...mentioning
confidence: 99%
See 2 more Smart Citations
“…44 There is recent evidence of interest in the use of AIMS in antidoping, with ASAP being utilized for the analysis of anabolic steroids 45 and both DESI and PS-MS for the rapid detection of stimulants and diuretics in urine. 46 The development of ambient ionization techniques for the analysis of explosives also constitutes a notable proportion of applications in forensic science. The rapid detection and identification of explosives are of crucial importance to national security, and the development of techniques that could feasibly be installed in airports and used on-site at incident scenes are of particular interest.…”
Section: Kim Et Al Used Sfpesi For the Rapid Detection Of Cocaine Met...mentioning
confidence: 99%
“…Numerous other AIMS techniques have proven capable in the analysis of controlled substances, including coated blade spray (CBS), 42 PS‐MS, 43 and thermal desorption‐assisted DBD 44 . There is recent evidence of interest in the use of AIMS in anti‐doping, with ASAP being utilized for the analysis of anabolic steroids 45 and both DESI and PS‐MS for the rapid detection of stimulants and diuretics in urine 46 …”
Section: Applications Of Aimsmentioning
confidence: 99%
See 1 more Smart Citation
“…Assessing the opposite approach, that is, omitting (largely) sample preparation and chromatography and employing desorption electrospray as well as paperspray ionization HRAM MS, was conducted by Bressan et al 97 Urine was analyzed as raw matrix or subjected to SPE, with the urine or the extracts deposited on different supports (polytetrafluoroethylene, C‐18‐ and cellulose‐based chromatographic paper). The dried samples were then either desorbed with methanol/water (80:20, v / v ) or sprayed with acetonitrile/water (85:15, v / v ) into a Q/Orbitrap MS, operated in positive and negative ionization mode.…”
Section: Diuretics and Masking Agents Stimulants And Narcoticsmentioning