2018
DOI: 10.1590/1517-869220182402181470
|View full text |Cite
|
Sign up to set email alerts
|

Postural Control Analysis During a Standardized Kick Task in Soccer Athletes

Abstract: Introduction: Postural control is a determining factor for functional performance and motor skills during sports activities. Objective: The objective of this study was to investigate postural control during the controlled soccer ball kicking task through a biomechanical analysis system. Methods: The sample consisted of 11 professional male athletes recruited using convenience sampling, with a mean age of 22 years. The athletes performed twenty-five precision kicks at a target, with the ball in vertical motio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 26 publications
1
3
0
Order By: Relevance
“…Therefore, the three-dimensional system developed in the present study captured the participants' movement during the kicking task, in different planes/axes. The calibration results showed that the sensor presented a level of oscillation (g) range varying between -1 to +3 g, con rming that this device responded adequately to the acceleration to which it was submitted [32], which is in accordance with previous studies [22,31,32,33]. Furthermore, the platform presented an adequate connectivity, linearity and hysteresis as well as a satisfactory resolution and sensitivity of curves, combined with a structural rigidity and low weight.…”
Section: Discussionsupporting
confidence: 84%
See 2 more Smart Citations
“…Therefore, the three-dimensional system developed in the present study captured the participants' movement during the kicking task, in different planes/axes. The calibration results showed that the sensor presented a level of oscillation (g) range varying between -1 to +3 g, con rming that this device responded adequately to the acceleration to which it was submitted [32], which is in accordance with previous studies [22,31,32,33]. Furthermore, the platform presented an adequate connectivity, linearity and hysteresis as well as a satisfactory resolution and sensitivity of curves, combined with a structural rigidity and low weight.…”
Section: Discussionsupporting
confidence: 84%
“…Contrary to previous studies [34,35], the CoP measurement error found during the distributed load test was greater than the error observed during the application of the centralised load. This could have been caused by an uneven load distribution on the plate not well transferred to the four load cells or imperfections on the plate [22,35]. Though this characteristic appears to be negative, it showed that a system designed in this manner can reduce the hysteresis effects [21].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…All signals were collected simultaneously and analyzed using the software EMGLab V1.1 -EMG System do Brasil 23 .…”
Section: Methodsmentioning
confidence: 99%