Postoperative analgesia in children: A comparison of three different doses of caudal epidural morphine

Abstract: Background and Aims:Caudal epidural block is the most commonly used neuraxial block in children. Morphine has been used as a caudal additive for more than three decades. The aim of our study was to evaluate the efficacy and duration of analgesia of three different doses of caudal epidural morphine (CEM), and to find out the incidence of side effects.Material and Methods:This study was conducted on 75 patients of American Society of Anesthesiologists grades I and II, aged 2-12 years, undergoing lower abdominal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 13 publications
(19 reference statements)
1
9
0
Order By: Relevance
“…Our results were partially consistent with these reports, and therefore advocate that a single shot of morphine (our median dose = 0.03 mg·kg −1 ) via caudal block can provide analgesia that lasts less than 24 h and that the abovementioned dose does not significantly contribute to negative effects in infants. Our findings were also consistent with that of a recent study, which demonstrated that a low dose of morphine (0.03 mg·kg −1 ) can provide analgesia lasting up to 12 h with minimal side effects, while higher doses of morphine (0.07 mg·kg −1 ) are associated with sedation and respiratory depression .…”
Section: Discussionsupporting
confidence: 93%
“…Our results were partially consistent with these reports, and therefore advocate that a single shot of morphine (our median dose = 0.03 mg·kg −1 ) via caudal block can provide analgesia that lasts less than 24 h and that the abovementioned dose does not significantly contribute to negative effects in infants. Our findings were also consistent with that of a recent study, which demonstrated that a low dose of morphine (0.03 mg·kg −1 ) can provide analgesia lasting up to 12 h with minimal side effects, while higher doses of morphine (0.07 mg·kg −1 ) are associated with sedation and respiratory depression .…”
Section: Discussionsupporting
confidence: 93%
“…Saadawy et al reported that the duration of analgesia was 6.2±2.8 hours in patients who underwent caudal block and were administered 1 mg/kg of 0.25% bupivacaine, while it was 18.5±2.8 hours in patients who underwent caudal block and were administered 1 mg/kg bupivacaine added to 1 µg dexmetodomine 11. In another study, Baduni et al compared 1 mg/kg of 0.25% bupivacaine to clonidine added to the same dose of local anesthetic; he reported that the duration of analgesia was 295.00±41.78 min in the bupivacaine group and 724.80±60.29 min in the bupivacaine+clonidine group 12. Sanwatsarkar et al also performed caudal block with 0.75 mL/kg of 0.25% bupivacaine and added 50 µg/kg morphine for patients who underwent lower abdominal and urogenital surgeries; the duration of analgesia was 13.36±2.47 hours 13.…”
Section: Discussionmentioning
confidence: 99%
“…17 Several studies in older children (one to 12 years of age) also showed excellent analgesia, with rare respiratory depression (only requiring naloxone when morphine 70 μg/kg was used). 14,18 21…”