2011
DOI: 10.1167/iovs.10-6340
|View full text |Cite
|
Sign up to set email alerts
|

Postnatal Elongation of Eye Size in DBA/2J Mice Compared with C57BL/6J Mice: In Vivo Analysis with Whole-Eye OCT

Abstract: In D2 mice, postnatal elongation of AL is larger than that in B6 mice and is associated with a greater increase in ACD and IOP, which seems to be a causal factor. The ease of use, short acquisition time, and noninvasiveness of whole-eye OCT make it suitable for routine use in longitudinal studies of mouse models.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
42
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 47 publications
(52 citation statements)
references
References 47 publications
10
42
0
Order By: Relevance
“…S2). The trend of the AL and VCD of the WT mice was consistent with the previous studies as follows: AL increases during postnatal development, whereas the VCD decreases (60,61).…”
Section: Bsg Mutant Mice Display Typical Myopic Phenotypes In the Axialsupporting
confidence: 91%
“…S2). The trend of the AL and VCD of the WT mice was consistent with the previous studies as follows: AL increases during postnatal development, whereas the VCD decreases (60,61).…”
Section: Bsg Mutant Mice Display Typical Myopic Phenotypes In the Axialsupporting
confidence: 91%
“…Previously, SD-OCT has been used to quantify age-related and TLR ligand-mediated corneal thickness changes in mice [27][28][29] and to assess corneal reflectivity during a sterile wound healing response. 30 At baseline, the adult BALB/c cornea is approximately 10% thicker than the C57BL/6 cornea.…”
Section: Discussionmentioning
confidence: 99%
“…A corneal radius of curvature of 1.22 was used after calibrating retinal thickness measurements in the SD-OCT scans to thicknesses at corresponding positions (0.2-mm intervals) in histological sections through the optic nerve head of four mice; the value used was consistent with previous determinations in mice. [30][31][32][33][34] Because axial length influences image magnification, distances from the base of the optic nerve to anterior cornea were measured in paraffin sections (10-lm thickness; 320 magnification) at 3 and 6 months of age using Photoshop version 7 (Adobe Photosystems, Inc., San Jose, CA, USA). Measurements obtained in C57BL/6J (2.586 6 0.034, mean 6 SEM) and Rdh8 À/À Abca4 À/À (2.574 6 0.018, mean 6 SEM) mice (four eyes per group) were not significantly different (one-way ANOVA, P > 0.05).…”
Section: Acquisition and Analysis Of Fundus Af Sd-oct Imagesmentioning
confidence: 99%