2008
DOI: 10.2214/ajr.07.3082
|View full text |Cite
|
Sign up to set email alerts
|

Postmortem Whole-Body CT Angiography: Evaluation of Two Contrast Media Solutions

Abstract: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
100
1
6

Year Published

2009
2009
2022
2022

Publication Types

Select...
8
2

Relationship

4
6

Authors

Journals

citations
Cited by 182 publications
(111 citation statements)
references
References 10 publications
3
100
1
6
Order By: Relevance
“…[31][32][33][34] In porcine exvivo experiments distribution defects of injected gadolinium could be simulated within the porcine myocardium, which possibly can be correlated to a disturbed antemortem perfusion as well. 31 A combination of pmMRI and minimally invasive angiography will enhance the diagnostic performance of pm imaging.…”
Section: Discussionmentioning
confidence: 99%
“…[31][32][33][34] In porcine exvivo experiments distribution defects of injected gadolinium could be simulated within the porcine myocardium, which possibly can be correlated to a disturbed antemortem perfusion as well. 31 A combination of pmMRI and minimally invasive angiography will enhance the diagnostic performance of pm imaging.…”
Section: Discussionmentioning
confidence: 99%
“…Improving the diagnostic yield from post-mortem MR and CT imaging is currently an area of active research (Grabherr et al, 2008;Ross et al, 2008) with the aim of "Visible Humans" to have comparable accuracy to that of conventional autopsies. Several studies have been conducted in this field to date.…”
Section: Discussionmentioning
confidence: 99%
“…In order to perfuse a human body, paraffinum liquidum has proven to be the most appropriate [2]. The use of the more viscous paraffinum perliquidum however, may lead to significant extravasations, especially in regions with high autolytic activities such as the pancreas and gastric mucosa [40,42]. By diluting Angiofil Ò with a solvent such as decane, its viscosity can be decreased so as to enter the capillar-ies and become a contrast agent used in microangiography [43].By using Angiofil Ò together with paraffinum liquidum as solvent, as proposed according to the standardized protocol of PMCTA, the kinematic viscosity of the mixture is around 67-74 mm 2 /s (measured at 40 °C).…”
Section: Discussionmentioning